Please login if you have access to particular applications.
Deployment Details
Survey: - SS2010_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 46
Operation No.: 1
Gear: CTD 21,Conductivity CTD 21-SN 2312,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Oxygen-CTD 21-SBE 43-SN 1239,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 21 -CST-1016DR
When: 2010-02-10 22:10 to 2010-02-10 22:53 UTC
Where:
46° 01.3' S
156° 49.1' E
to
46° 01.3' S
156° 49.3' E
Maximum Depth (m): 998
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Orthophosphate (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|
| 1052 | 11.2 | 277.65 | 34.569 | 5.33 | 0.51 | 0.64 |
| 1064 | 26.7 | 5.56 | 0.52 | 0.66 | ||
| 1059 | 31.8 | 5.64 | 0.54 | 0.66 | ||
| 1062 | 46.7 | 7.17 | 0.67 | 0.98 | ||
| 1065 | 72.4 | 9.75 | 0.84 | 2.02 | ||
| 1060 | 97.7 | 266.17 | 34.630 | 14.16 | 1.01 | 3.79 |
| 1019 | 121.7 | 14.24 | 1.03 | 4.04 | ||
| 1067 | 147.1 | 14.55 | 1.03 | 4.19 | ||
| 1056 | 297.6 | 271.31 | 34.602 | 15.28 | 1.09 | 4.47 |
| 1057 | 497.6 | 18.82 | 1.29 | 6.90 | ||
| 1024 | 746.8 | 26.17 | 1.76 | 17.70 | ||
| 1068 | 996.4 | 203.51 | 34.384 | 30.47 | 2.06 | 31.91 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
| Conductivity CTD 21-SN 2312 | Seabird | SBE-4 | 2312 | |
| Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
| Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen-CTD 21-SBE 43-SN 1239 | Seabird | SBE 43 | 1239 | Oxygen (µM) |
| Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
| Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
| Transmissometer - CTD 21 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |