Deployment Details
Survey: - SS2010_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Operation No.: 1
Gear: Altitude CTD 21-41023,CTD 21,Conductivity CTD 21-SN 2312,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Nitrate - CTD21 Satlantic ISUS V3-076,Oxygen-CTD 21-SBE 43-SN 1239,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 21 -CST-1016DR
When: 2010-05-10 17:22 to 2010-05-10 18:00 UTC
Where:
21° 00.0' S
113° 40.0' E
to
21° 00.0' S
113° 40.1' E
Maximum Depth (m): 978
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Orthophosphate (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|
1064 | 1.1 | < 0.02 | < 0.02 | 2.33 | ||
1066 | 39 | 202.17 | 35.205 | < 0.02 | < 0.02 | 2.33 |
1059 | 77.5 | < 0.02 | 0.05 | 2.46 | ||
1062 | 89 | 0.75 | 0.19 | 4.82 | ||
1065 | 107.5 | 2.39 | 0.28 | 5.63 | ||
1060 | 127 | 6.77 | 0.50 | 7.72 | ||
1067 | 293.2 | 7.37 | 0.56 | 6.63 | ||
1056 | 390.3 | 14.87 | 1.04 | 10.74 | ||
1057 | 487.2 | 20.63 | 1.41 | 16.50 | ||
1024 | 733.1 | 35.03 | 2.47 | 67.85 | ||
1068 | 977 | 93.78 | 34.637 | 37.51 | 2.69 | 90.44 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altitude CTD 21-41023 | PSA | 916T | 41023 | Altitude(m) |
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21-SN 2312 | Seabird | SBE-4 | 2312 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Nitrate - CTD21 Satlantic ISUS V3-076 | Satlantic | V3 | 076 | Nitrate (µM) |
Oxygen-CTD 21-SBE 43-SN 1239 | Seabird | SBE 43 | 1239 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Transmissometer - CTD 21 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |