Deployment Details
Survey: - SS200604 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 156
Operation No.: 1
Gear: AAD Par Sensor(volts),CTD 19,Conductivity CTD 19-SN 2594,Fluorometer CTD 19-Chelsea 88221,Oxygen CTD 19-Beckman 526,Oxygen-CTD 19-Optode SN 583-Foil 4104,Pressure CTD 19-SN 75637,Temperature CTD 19-SN 2334,Transmissometer - CTD 19 -CST-1016DR
When: 2006-04-25 07:17 to 2006-04-25 09:30 UTC
Where:
35° 16.2' S
115° 32.4' E
to
35° 16.4' S
115° 32.4' E
Maximum Depth (m): 3026
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Orthophosphate (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|
1024 | 13.5 | < 0.02 | < 0.02 | 1.42 | ||
1006 | 30.1 | 238.79 | 35.731 | < 0.02 | < 0.02 | 1.36 |
1017 | 48.7 | 0.05 | 0.03 | 1.19 | ||
1023 | 70.6 | 0.23 | 0.04 | 0.89 | ||
1004 | 89.3 | 0.37 | 0.05 | 0.99 | ||
1047 | 110.9 | 0.81 | 0.08 | 1.56 | ||
1043 | 208.8 | 246.43 | 35.239 | 5.54 | 0.38 | 1.30 |
1005 | 310 | 10.76 | 0.67 | 2.20 | ||
1013 | 510.3 | 17.06 | 1.02 | 4.55 | ||
1022 | 759.7 | 27.99 | 1.66 | 18.90 | ||
1019 | 1009.2 | 33.81 | 2.07 | 43.26 | ||
1002 | 2009.7 | 35.23 | 2.23 | 98.74 | ||
1045 | 3039.2 | 192.48 | 34.735 | 32.61 | 2.41 | 153.46 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
AAD Par Sensor(volts) | PAR_VOLTS(volts) | |||
CTD 19 | Seabird | SBE II plus | 0551 | |
Conductivity CTD 19-SN 2594 | Seabird | SBE-4 | 2594 | |
Fluorometer CTD 19-Chelsea 88221 | Chelsea | 88221 | Fluorescence (arbitrary units) | |
Oxygen CTD 19-Beckman 526 | Seabird | Beckman | 130526 | Oxygen (µM) |
Oxygen-CTD 19-Optode SN 583-Foil 4104 | Aanderaa | Optode 3975 | 583 | Optode (micromole/litre) |
Pressure CTD 19-SN 75637 | Paroscientific I | 410K-105 | 75637 | Pressure (decibars) |
Temperature CTD 19-SN 2334 | Seabird | SBE-3 | 2334 | Temperature (deg C) |
Transmissometer - CTD 19 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |