Deployment Details
Survey: - SS200604 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 119
Operation No.: 1
Gear: AAD Par Sensor(volts),CTD 19,Conductivity CTD 19-SN 2594,Fluorometer CTD 19-Chelsea 88221,Oxygen CTD 19-Beckman 526,Oxygen-CTD 19-Optode SN 583-Foil 4104,Pressure CTD 19-SN 75637,Temperature CTD 19-SN 2334,Transmissometer - CTD 19 -CST-1016DR
When: 2006-04-22 20:16 to 2006-04-22 21:33 UTC
Where:
35° 35.3' S
117° 50.0' E
to
35° 35.3' S
117° 50.0' E
Maximum Depth (m): 1698
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Orthophosphate (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|
1024 | 16.1 | < 0.02 | 0.07 | 0.80 | ||
1006 | 29.1 | 242.68 | 35.555 | < 0.02 | 0.07 | 0.70 |
1017 | 50.1 | 0.05 | 0.08 | 0.56 | ||
1023 | 68.1 | 0.19 | 0.11 | 0.46 | ||
1004 | 88.5 | 0.32 | 0.12 | 0.58 | ||
1047 | 110.4 | 0.82 | 0.16 | 0.59 | ||
1043 | 129.6 | 2.77 | 0.30 | 0.66 | ||
1005 | 209.5 | 248.93 | 35.060 | 7.52 | 0.58 | 1.33 |
1013 | 308.2 | 12.31 | 0.86 | 2.53 | ||
1022 | 509.2 | 16.29 | 1.09 | 4.29 | ||
1019 | 760.3 | 26.40 | 1.76 | 18.41 | ||
1002 | 1008.4 | 193.11 | 34.397 | 32.10 | 2.20 | 44.04 |
1045 | 1709.1 | 165.15 | 34.643 | 33.71 | 2.38 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
AAD Par Sensor(volts) | PAR_VOLTS(volts) | |||
CTD 19 | Seabird | SBE II plus | 0551 | |
Conductivity CTD 19-SN 2594 | Seabird | SBE-4 | 2594 | |
Fluorometer CTD 19-Chelsea 88221 | Chelsea | 88221 | Fluorescence (arbitrary units) | |
Oxygen CTD 19-Beckman 526 | Seabird | Beckman | 130526 | Oxygen (µM) |
Oxygen-CTD 19-Optode SN 583-Foil 4104 | Aanderaa | Optode 3975 | 583 | Optode (micromole/litre) |
Pressure CTD 19-SN 75637 | Paroscientific I | 410K-105 | 75637 | Pressure (decibars) |
Temperature CTD 19-SN 2334 | Seabird | SBE-3 | 2334 | Temperature (deg C) |
Transmissometer - CTD 19 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |