Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 100
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-06-02 22:32 to 2007-06-03 00:13 UTC
Where:
22° 59.9' S
112° 18.4' E
to
22° 58.6' S
112° 16.8' E
Maximum Depth (m): 1950
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1070 | 0.7 | 24.95 | ||||||
1069 | 0.7 | 0.05 | 24.95 | 0.04 | 0.06 | 2.55 | ||
1068 | 7.8 | 0.04 | 24.95 | 0.05 | 0.04 | 2.59 | ||
1065 | 22.6 | 208.80 | 35.237 | < 0.02 | 24.96 | 0.04 | 0.04 | 2.56 |
1066 | 22.7 | 24.96 | ||||||
1063 | 47.6 | < 0.02 | 24.76 | 0.04 | 0.03 | 2.52 | ||
1064 | 47.8 | 24.76 | ||||||
1060 | 64 | 24.56 | ||||||
1062 | 64 | 24.55 | ||||||
1061 | 64.1 | 24.55 | ||||||
1059 | 64.2 | 0.53 | 24.56 | 0.08 | 0.19 | 3.15 | ||
1058 | 98.2 | 2.62 | 23.08 | 0.27 | 0.07 | 4.98 | ||
1067 | 123.9 | 4.59 | 21.32 | 0.40 | 0.03 | 6.38 | ||
1056 | 248.5 | 1.50 | 18.04 | 0.21 | 0.03 | 2.12 | ||
1055 | 499.1 | 19.05 | 8.50 | 1.33 | 0.04 | 8.29 | ||
1054 | 1002.8 | 36.30 | 4.92 | 2.61 | < 0.02 | 84.26 | ||
1053 | 1499.5 | 34.74 | 3.43 | 2.56 | < 0.02 | 98.41 | ||
1052 | 1944.6 | 149.60 | 34.717 | 32.65 | 2.40 | 2.49 | < 0.02 | 113.24 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |