Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 94
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-06-01 17:39 to 2007-06-01 18:31 UTC
Where:
23° 59.9' S
111° 58.6' E
to
23° 59.8' S
111° 58.6' E
Maximum Depth (m): 952
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1066 | 1.1 | 0.02 | 24.88 | 0.03 | < 0.02 | 2.88 | ||
1070 | 1.6 | 24.87 | ||||||
1068 | 1.7 | 24.87 | ||||||
1069 | 1.9 | 24.87 | ||||||
1065 | 7.7 | < 0.02 | 24.88 | 0.04 | 0.03 | 2.92 | ||
1063 | 22.2 | 102.50 | 35.170 | < 0.02 | 24.89 | 0.03 | < 0.02 | 2.86 |
1064 | 22.4 | 24.89 | ||||||
1059 | 43.4 | 0.04 | 24.90 | 0.03 | < 0.02 | 2.94 | ||
1060 | 43.9 | 24.90 | ||||||
1061 | 44.2 | 24.90 | ||||||
1062 | 44.4 | 24.90 | ||||||
1058 | 74.6 | 0.58 | 24.94 | 0.07 | < 0.02 | 3.29 | ||
1067 | 98.1 | 22.23 | ||||||
1056 | 98.1 | 5.37 | 22.22 | 0.43 | < 0.02 | 7.55 | ||
1055 | 123 | 5.74 | 21.63 | 0.43 | < 0.02 | 7.27 | ||
1054 | 248.4 | 3.13 | 18.02 | 0.26 | < 0.02 | 3.37 | ||
1053 | 496.4 | 14.74 | 9.93 | 1.02 | < 0.02 | 4.89 | ||
1052 | 947.5 | 209.10 | 34.619 | 36.39 | 5.26 | 2.61 | < 0.02 | 86.34 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |