Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 91
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-31 22:25 to 2007-05-31 22:45 UTC
Where:
25° 00.0' S
112° 11.1' E
to
25° 00.0' S
112° 11.1' E
Maximum Depth (m): 250
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1068 | 1.5 | 24.82 | ||||||
1066 | 1.5 | < 0.02 | 24.82 | < 0.02 | < 0.02 | 2.05 | ||
1070 | 1.7 | 24.85 | ||||||
1069 | 1.7 | 24.85 | ||||||
1065 | 8.3 | 0.07 | 24.87 | < 0.02 | < 0.02 | 2.08 | ||
1064 | 22.8 | 24.87 | ||||||
1063 | 23.2 | 210.10 | 35.244 | 0.02 | 24.87 | < 0.02 | < 0.02 | 2.07 |
1061 | 48.4 | 0.02 | 24.79 | 0.05 | < 0.02 | 2.12 | ||
1062 | 48.7 | 24.78 | ||||||
1058 | 67.4 | 24.34 | ||||||
1059 | 67.6 | 24.33 | ||||||
1060 | 67.7 | 24.30 | ||||||
1067 | 67.8 | 0.26 | 24.31 | 0.04 | < 0.02 | 2.49 | ||
1056 | 98.5 | < 0.02 | 23.15 | < 0.02 | < 0.02 | 2.25 | ||
1055 | 122 | 0.44 | 22.24 | 0.10 | 0.07 | 3.02 | ||
1054 | 149.1 | 0.03 | 21.93 | 0.03 | < 0.02 | 2.10 | ||
1053 | 198.6 | 3.33 | 19.47 | 0.29 | < 0.02 | 3.88 | ||
1052 | 249.9 | 219.20 | 35.853 | 1.62 | 18.08 | 0.18 | < 0.02 | 1.99 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |