Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 88
Operation No.: 1
Gear: CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-31 10:27 to 2007-05-31 11:13 UTC
Where:
25° 00.0' S
111° 32.8' E
to
25° 00.1' S
111° 33.5' E
Maximum Depth (m): 952
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|
1068 | 1.8 | 25.00 | |||||
1066 | 1.8 | < 0.02 | 25.00 | 0.03 | < 0.02 | 2.35 | |
1069 | 1.8 | 24.99 | |||||
1070 | 1.9 | 25.00 | |||||
1065 | 8.6 | < 0.02 | 24.99 | 0.04 | < 0.02 | 2.42 | |
1063 | 23.1 | < 0.02 | 24.99 | 0.04 | < 0.02 | 2.38 | |
1064 | 23.7 | 24.99 | |||||
1060 | 37.9 | 24.98 | |||||
1062 | 38.2 | 192.60 | 24.98 | ||||
1061 | 38.7 | 24.99 | |||||
1059 | 38.9 | < 0.02 | 24.99 | 0.04 | < 0.02 | 2.54 | |
1067 | 72.5 | 5.31 | 22.14 | 0.40 | 0.04 | 6.26 | |
1058 | 73.5 | 22.13 | |||||
1056 | 98.8 | 0.25 | 22.43 | 0.08 | 0.18 | 2.68 | |
1055 | 147.6 | 0.31 | 21.11 | 0.08 | 0.06 | 2.20 | |
1054 | 248.5 | 3.75 | 16.63 | 0.32 | < 0.02 | 2.43 | |
1053 | 497.6 | 248.70 | 17.88 | 9.55 | 1.08 | < 0.02 | 3.89 |
1052 | 950.3 | 40.11 | 5.07 | 2.59 | 70.30 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |