Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 85
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-30 13:02 to 2007-05-30 13:16 UTC
Where:
26° 00.1' S
112° 19.7' E
to
26° 00.1' S
112° 19.7' E
Maximum Depth (m): 176
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1060 | 0.9 | < 0.02 | 24.00 | 0.03 | < 0.02 | 1.98 | ||
1059 | 18.7 | 214.10 | 35.437 | < 0.02 | 24.01 | 0.03 | < 0.02 | 2.04 |
1058 | 37.5 | < 0.02 | 23.89 | < 0.02 | < 0.02 | 2.00 | ||
1067 | 60.4 | < 0.02 | 23.60 | < 0.02 | < 0.02 | 2.08 | ||
1056 | 77.6 | < 0.02 | 23.43 | 0.03 | < 0.02 | 2.17 | ||
1055 | 98.8 | 0.20 | 22.76 | 0.09 | 0.08 | 2.86 | ||
1054 | 122.7 | 0.65 | 22.10 | 0.10 | 0.13 | 2.53 | ||
1053 | 149.1 | 210.30 | 35.742 | 1.39 | 20.85 | 0.15 | 0.03 | 2.94 |
1052 | 173.6 | 3.01 | 20.14 | 0.19 | < 0.02 | 3.40 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |