Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 82
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-30 00:48 to 2007-05-30 01:40 UTC
Where:
25° 59.5' S
111° 36.8' E
to
25° 58.8' S
111° 36.1' E
Maximum Depth (m): 954
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1069 | 2.6 | 23.22 | ||||||
1070 | 2.7 | 23.22 | ||||||
1065 | 2.8 | 0.59 | 23.23 | 0.05 | < 0.02 | 2.35 | ||
1068 | 2.9 | 23.23 | ||||||
1066 | 3 | 23.22 | ||||||
1064 | 8.5 | 0.03 | 23.23 | 0.05 | < 0.02 | 3.02 | ||
1063 | 23.1 | 23.24 | ||||||
1062 | 23.8 | 113.40 | 35.562 | 0.03 | 23.23 | 0.04 | < 0.02 | 2.29 |
1059 | 48.6 | 22.79 | ||||||
1060 | 49.6 | 22.79 | ||||||
1058 | 49.8 | < 0.02 | 22.79 | 0.08 | < 0.02 | 2.55 | ||
1061 | 50.5 | 22.79 | ||||||
1067 | 73.9 | 0.46 | 22.62 | 0.08 | 0.25 | 2.59 | ||
1056 | 100.5 | 1.10 | 21.10 | 0.15 | 0.13 | 2.98 | ||
1055 | 125.6 | 1.37 | 19.88 | 0.20 | 0.04 | 2.98 | ||
1054 | 252 | 3.59 | 14.99 | 0.38 | < 0.02 | 1.49 | ||
1053 | 498.5 | 20.92 | 8.36 | 1.47 | < 0.02 | 8.64 | ||
1052 | 951.6 | 215.80 | 34.607 | 36.04 | 4.63 | 2.86 | < 0.02 | 85.78 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |