Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 78
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-28 21:06 to 2007-05-28 21:26 UTC
Where:
26° 59.9' S
112° 42.6' E
to
26° 59.9' S
112° 42.9' E
Maximum Depth (m): 272
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1069 | 1.5 | 23.62 | ||||||
1066 | 1.5 | < 0.02 | 23.61 | < 0.02 | < 0.02 | 2.01 | ||
1068 | 1.6 | 23.62 | ||||||
1070 | 1.8 | 23.65 | ||||||
1065 | 8.3 | < 0.02 | 23.62 | < 0.02 | < 0.02 | 1.99 | ||
1063 | 22.2 | 214.80 | 35.524 | < 0.02 | 23.63 | 0.09 | < 0.02 | 2.03 |
1064 | 22.8 | 23.62 | ||||||
1061 | 46.9 | < 0.02 | 23.63 | < 0.02 | < 0.02 | 2.01 | ||
1062 | 47.7 | 23.63 | ||||||
1059 | 72.3 | 23.63 | ||||||
1058 | 72.7 | 23.61 | ||||||
1067 | 72.8 | 0.03 | 23.61 | < 0.02 | 0.07 | 2.17 | ||
1060 | 73.5 | 23.64 | ||||||
1056 | 97.5 | 1.61 | 22.60 | 0.16 | 0.08 | 4.05 | ||
1055 | 121.7 | 0.04 | 22.68 | 0.04 | 0.05 | 2.35 | ||
1054 | 151.2 | 1.43 | 21.65 | 0.16 | 0.10 | 3.30 | ||
1053 | 198 | 0.52 | 19.83 | 0.10 | 0.10 | 2.06 | ||
1052 | 271.9 | 231.70 | 35.648 | 2.79 | 15.77 | 0.27 | < 0.02 | 1.64 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |