Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 74
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-28 01:25 to 2007-05-28 02:54 UTC
Where: 
27° 59.1' S   
112° 22.0' E
 to 
27° 59.4' S   
112° 23.0' E
Maximum Depth (m): 1920
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
| Bottle Number | Pressure | Salinity (psu) | Nitrate (µM) | Temperature (deg C) | Orthophosphate (µM) | Ammonia (µM) | Silicate (µM) | 
|---|---|---|---|---|---|---|---|
| 1068 | 1.6 | < 0.02 | 20.49 | < 0.02 | < 0.02 | 1.95 | |
| 1066 | 6.3 | 35.967 | < 0.02 | 20.49 | 0.04 | < 0.02 | 1.92 | 
| 1065 | 23 | 20.49 | |||||
| 1064 | 47.7 | 20.50 | |||||
| 1063 | 71.8 | 20.51 | |||||
| 1062 | 71.9 | 20.50 | |||||
| 1060 | 99 | 19.13 | |||||
| 1067 | 99.8 | 0.21 | 18.79 | 0.10 | < 0.02 | 1.65 | |
| 1059 | 99.8 | 18.93 | |||||
| 1058 | 101 | 18.78 | |||||
| 1056 | 120.8 | 1.37 | 17.93 | 0.20 | 0.09 | 2.90 | |
| 1055 | 251.3 | 6.26 | 12.97 | 0.51 | < 0.02 | 1.33 | |
| 1054 | 497.1 | 14.96 | 9.52 | 1.07 | < 0.02 | 4.01 | |
| 1053 | 996 | 32.35 | 4.45 | 2.42 | < 0.02 | 60.45 | |
| 1052 | 1497.7 | 35.05 | 3.13 | 2.55 | < 0.02 | 90.47 | |
| 1061 | 1916.5 | 34.702 | 33.86 | 2.48 | 2.58 | < 0.02 | 105.88 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) | 
| CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
| Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
| Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) | 
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) | 
| Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) | 
| Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) | 
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) | 
| Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |