Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 72
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-27 18:44 to 2007-05-27 19:16 UTC
Where:
28° 00.0' S
113° 05.8' E
to
28° 00.5' S
113° 06.3' E
Maximum Depth (m): 448
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|
1062 | 2.3 | < 0.02 | 23.92 | 0.05 | < 0.02 | 2.12 | |
1060 | 9.9 | < 0.02 | 23.92 | 0.10 | < 0.02 | 2.11 | |
1059 | 28.9 | 35.453 | 0.02 | 23.77 | 0.04 | < 0.02 | 2.17 |
1058 | 48.6 | 0.29 | 23.51 | 0.05 | < 0.02 | 2.48 | |
1067 | 74 | 0.16 | 22.89 | 0.08 | 0.05 | 2.42 | |
1056 | 99.4 | 0.18 | 22.07 | 0.06 | 0.04 | 2.25 | |
1055 | 123.9 | 0.45 | 20.77 | 0.11 | 0.07 | 2.33 | |
1054 | 147.7 | 0.02 | 20.54 | 0.05 | < 0.02 | 1.81 | |
1053 | 198.4 | 0.02 | 19.22 | 0.11 | < 0.02 | 1.43 | |
1052 | 299.6 | 7.00 | 12.84 | 0.61 | < 0.02 | 1.50 | |
1061 | 441.3 | 34.689 | 16.29 | 9.30 | 1.18 | < 0.02 | 4.20 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |