Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 69
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-27 08:12 to 2007-05-27 08:24 UTC
Where:
27° 59.9' S
113° 45.4' E
to
27° 59.9' S
113° 45.4' E
Maximum Depth (m): 40
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|
1063 | 0.2 | 22.64 | |||||
1062 | 0.3 | 35.474 | 22.64 | ||||
1065 | 0.5 | 22.64 | |||||
1066 | 0.6 | 22.64 | |||||
1060 | 0.6 | < 0.02 | 22.64 | 0.10 | < 0.02 | 2.11 | |
1068 | 0.7 | 22.64 | |||||
1064 | 0.7 | 22.64 | |||||
1059 | 8.6 | < 0.02 | 22.65 | 0.10 | < 0.02 | 2.07 | |
1058 | 22.8 | 22.19 | |||||
1067 | 22.9 | < 0.02 | 22.20 | 0.10 | < 0.02 | 1.41 | |
1056 | 32.8 | 21.90 | |||||
1055 | 33 | 21.90 | |||||
1054 | 33.1 | 21.90 | |||||
1053 | 33.3 | 0.11 | 21.90 | 0.12 | < 0.02 | 1.52 | |
1061 | 40.2 | 21.89 | |||||
1052 | 40.3 | 35.596 | 0.21 | 21.89 | 0.14 | < 0.02 | 1.68 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |