Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 61
Operation No.: 1
Gear: CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-25 10:26 to 2007-05-25 10:40 UTC
Where:
29° 59.8' S
114° 28.3' E
to
29° 59.9' S
114° 28.3' E
Maximum Depth (m): 102
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|
1065 | 1.9 | 0.06 | 22.49 | 0.09 | 0.21 | 1.89 |
1068 | 2.5 | 22.49 | ||||
1066 | 2.8 | 22.49 | ||||
1063 | 8.7 | 0.09 | 22.50 | 0.09 | 0.22 | 1.89 |
1064 | 8.8 | 22.49 | ||||
1060 | 23 | 22.50 | ||||
1061 | 23.2 | 22.49 | ||||
1059 | 23.8 | 22.50 | ||||
1058 | 23.9 | 0.09 | 22.50 | 0.08 | 0.24 | 1.89 |
1062 | 24.2 | 22.50 | ||||
1056 | 47.3 | 0.12 | 22.45 | 0.09 | 0.26 | 1.94 |
1067 | 47.5 | 22.45 | ||||
1054 | 72.4 | 0.14 | 22.37 | 0.09 | 0.30 | 1.98 |
1055 | 73 | 22.39 | ||||
1052 | 98.7 | 0.14 | 22.27 | 0.10 | 0.32 | 1.95 |
1053 | 99.5 | 22.28 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |