Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 58
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-25 03:14 to 2007-05-25 04:09 UTC
Where:
29° 59.9' S
114° 13.3' E
to
30° 00.2' S
114° 13.8' E
Maximum Depth (m): 906
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1064 | 2.1 | < 0.02 | 22.83 | |||||
1063 | 8.2 | < 0.02 | 22.84 | |||||
1062 | 22.9 | 221.70 | 35.607 | < 0.02 | 22.65 | |||
1061 | 47.3 | < 0.02 | 22.59 | |||||
1060 | 72.4 | < 0.02 | 22.49 | 2.18 | ||||
1059 | 98.2 | 0.06 | 22.40 | 0.08 | 0.40 | 2.66 | ||
1058 | 125.4 | 0.64 | 22.46 | 0.08 | 0.31 | 2.68 | ||
1067 | 147 | 0.62 | 22.20 | 0.15 | < 0.02 | 2.88 | ||
1056 | 199.7 | 1.27 | 20.09 | 0.31 | < 0.02 | 1.34 | ||
1055 | 297.9 | 2.91 | 15.29 | |||||
1054 | 497 | 15.87 | 9.46 | 1.09 | < 0.02 | 4.03 | ||
1053 | 747 | 204.90 | 34.417 | 28.32 | 5.87 | 1.98 | < 0.02 | 25.10 |
1052 | 903.9 | 30.79 | 4.81 | 2.18 | < 0.02 | 38.00 | ||
1057 | 904.1 | 4.78 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |