Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 57
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-24 22:52 to 2007-05-25 00:24 UTC
Where:
30° 00.0' S
113° 58.2' E
to
30° 01.1' S
113° 59.3' E
Maximum Depth (m): 1950
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1070 | 1.6 | 23.03 | ||||||
1069 | 2.1 | 0.12 | 23.04 | 0.08 | 0.06 | 2.47 | ||
1068 | 8.7 | 0.14 | 23.05 | 0.08 | 0.06 | 2.48 | ||
1065 | 22.5 | 218.20 | 34.790 | 0.13 | 23.04 | 0.08 | 0.06 | 2.44 |
1066 | 22.5 | 23.04 | ||||||
1064 | 47.8 | 23.05 | ||||||
1063 | 47.8 | 0.15 | 23.05 | 0.10 | 0.06 | 2.46 | ||
1062 | 61.5 | 23.06 | ||||||
1061 | 62.5 | 23.06 | ||||||
1059 | 63 | 23.06 | ||||||
1060 | 63.2 | 23.06 | ||||||
1058 | 74.1 | 0.17 | 23.06 | 0.11 | 2.52 | |||
1067 | 97.9 | 0.24 | 22.63 | 0.10 | 0.15 | 2.60 | ||
1056 | 123.8 | 0.29 | 21.96 | 0.06 | 0.11 | 2.49 | ||
1055 | 251.3 | 0.27 | 15.93 | 0.06 | 0.17 | 2.37 | ||
1054 | 501.4 | 1.02 | 9.60 | 0.61 | < 0.02 | 1.39 | ||
1053 | 999.8 | 34.05 | 4.45 | 2.55 | < 0.02 | 65.80 | ||
1052 | 1500.3 | 34.50 | 3.13 | 2.58 | < 0.02 | 84.51 | ||
1057 | 1948.2 | 166.80 | 35.609 | 33.92 | 2.42 | 2.51 | < 0.02 | 101.93 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |