Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 50
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-23 19:54 to 2007-05-23 20:46 UTC
Where:
31° 00.0' S
114° 39.6' E
to
31° 01.2' S
114° 40.4' E
Maximum Depth (m): 960
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1063 | 2.7 | 0.03 | 22.14 | 0.08 | 0.18 | 2.36 | ||
1062 | 22.8 | 223.60 | 35.657 | < 0.02 | 22.13 | |||
1061 | 49.2 | 0.56 | 22.10 | 0.05 | < 0.02 | 1.93 | ||
1060 | 73.6 | 0.03 | 21.45 | 0.06 | 2.27 | |||
1059 | 99 | 0.10 | 21.23 | 0.07 | 0.08 | 2.48 | ||
1058 | 122 | 0.23 | 21.15 | 0.08 | 0.16 | 4.01 | ||
1067 | 146.6 | 0.12 | 20.81 | 0.06 | 0.08 | 3.73 | ||
1056 | 200.3 | 0.93 | 18.62 | 0.15 | 0.03 | |||
1055 | 299.5 | 5.67 | 13.41 | 0.47 | < 0.02 | 1.29 | ||
1054 | 500.6 | 16.35 | 9.08 | 1.13 | < 0.02 | 4.63 | ||
1053 | 750.6 | 29.61 | 5.07 | 2.03 | 0.03 | 32.85 | ||
1057 | 955.8 | 4.15 | ||||||
1052 | 957 | 162.90 | 34.483 | 34.21 | 4.15 | 2.42 | < 0.02 | 63.32 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |