Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 49
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-23 15:50 to 2007-05-23 16:44 UTC
Where:
31° 00.0' S
114° 34.3' E
to
31° 00.8' S
114° 35.5' E
Maximum Depth (m): 1232
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1066 | 1.8 | 0.32 | 21.17 | 0.08 | 0.20 | 2.53 | ||
1068 | 2 | 21.17 | ||||||
1069 | 2.1 | 21.17 | ||||||
1070 | 2.1 | 21.17 | ||||||
1065 | 9.1 | 0.32 | 21.17 | 0.09 | 0.19 | 2.53 | ||
1064 | 22.8 | 21.18 | ||||||
1063 | 23 | 227.00 | 34.562 | 0.35 | 21.18 | 0.09 | 0.18 | 2.73 |
1062 | 47.7 | 21.18 | ||||||
1061 | 47.9 | 0.33 | 21.18 | 0.10 | 0.20 | 2.53 | ||
1060 | 73.3 | 0.31 | 21.19 | 0.08 | 0.16 | 2.54 | ||
1067 | 98.1 | 21.19 | ||||||
1058 | 98.3 | 21.19 | ||||||
1056 | 98.4 | 0.35 | 21.19 | 0.08 | 0.17 | 2.56 | ||
1059 | 99 | 21.19 | ||||||
1055 | 146.8 | 0.35 | 20.82 | 0.08 | 0.24 | 2.07 | ||
1054 | 249.9 | 1.97 | 15.72 | 0.25 | < 0.02 | 1.41 | ||
1053 | 501.1 | 20.47 | 8.28 | < 0.02 | 8.40 | |||
1052 | 998.2 | 34.95 | 4.06 | 2.50 | < 0.02 | 69.67 | ||
1057 | 1228.1 | 156.70 | 35.755 | 35.00 | 3.52 | 2.56 | < 0.02 | 79.92 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |