Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 42
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-22 11:52 to 2007-05-22 12:22 UTC
Where:
31° 00.0' S
112° 14.8' E
to
31° 00.8' S
112° 14.1' E
Maximum Depth (m): 502
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1068 | 1.5 | < 0.02 | 22.75 | 0.06 | < 0.02 | 1.91 | ||
1069 | 1.6 | 22.75 | ||||||
1070 | 1.7 | 22.75 | ||||||
1066 | 2 | < 0.02 | 22.75 | 0.05 | < 0.02 | 1.86 | ||
1065 | 8.3 | 218.70 | 22.73 | |||||
1063 | 22 | 22.75 | ||||||
1064 | 23.1 | < 0.02 | 22.74 | 0.05 | < 0.02 | 1.84 | ||
1061 | 35.9 | 22.82 | ||||||
1060 | 36.1 | 0.22 | 22.83 | 0.04 | 0.06 | 2.56 | ||
1062 | 36.2 | 22.83 | ||||||
1059 | 38.7 | 22.87 | ||||||
1058 | 58.2 | 22.33 | ||||||
1067 | 58.2 | 0.16 | 22.33 | 0.08 | 0.08 | 2.55 | ||
1056 | 98.3 | 0.76 | 22.00 | 0.11 | 0.25 | 2.61 | ||
1055 | 148.8 | 0.49 | 20.61 | 0.08 | 0.12 | 2.23 | ||
1054 | 197.6 | 0.97 | 17.45 | 0.17 | < 0.02 | 1.60 | ||
1053 | 299.5 | 244.70 | 35.219 | 6.85 | 12.90 | < 0.02 | 1.40 | |
1052 | 499.1 | 9.13 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |