Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 33
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-19 12:22 to 2007-05-19 13:54 UTC
Where:
31° 53.6' S
114° 42.4' E
to
31° 53.7' S
114° 43.0' E
Maximum Depth (m): 2102
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1068 | 0.9 | 0.03 | 20.57 | 0.03 | < 0.02 | 2.38 | ||
1069 | 1.1 | 20.57 | ||||||
1070 | 1.4 | 20.57 | ||||||
1066 | 8.5 | 0.03 | 20.57 | 0.04 | < 0.02 | 2.40 | ||
1065 | 23.2 | 20.58 | ||||||
1064 | 23.3 | 148.00 | 35.879 | 0.03 | 20.58 | 0.04 | < 0.02 | 2.34 |
1062 | 48.2 | 0.02 | 20.43 | 0.04 | < 0.02 | 2.23 | ||
1063 | 48.7 | 20.43 | ||||||
1061 | 56.6 | 20.31 | ||||||
1060 | 57.7 | 0.30 | 20.31 | 0.06 | 0.07 | 2.28 | ||
1059 | 57.9 | 1.18 | 20.31 | 0.16 | < 0.02 | 2.46 | ||
1058 | 100.5 | 0.52 | 18.64 | 0.14 | 0.09 | 1.83 | ||
1067 | 123.8 | 6.59 | 17.60 | 0.54 | < 0.02 | 1.50 | ||
1056 | 248.9 | 16.73 | 12.96 | 1.15 | < 0.02 | 4.09 | ||
1055 | 499.6 | 36.08 | 9.36 | 2.56 | < 0.02 | 61.68 | ||
1054 | 1000.4 | 36.29 | 4.07 | < 0.02 | 83.39 | |||
1053 | 1499.1 | 141.20 | 34.611 | 34.99 | 2.97 | 2.53 | < 0.02 | 108.07 |
1052 | 2100.1 | 2.25 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |