Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 25
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-18 05:17 to 2007-05-18 06:12 UTC
Where:
33° 00.0' S
114° 15.4' E
to
33° 00.1' S
114° 15.6' E
Maximum Depth (m): 950
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1062 | 1.8 | 0.19 | 20.51 | 0.03 | 0.07 | 2.19 | ||
1061 | 22.9 | 228.90 | 35.877 | 0.18 | 20.52 | 0.03 | 0.05 | 2.13 |
1060 | 50.3 | 0.19 | 20.45 | < 0.02 | < 0.02 | 2.11 | ||
1059 | 72.1 | < 0.02 | 20.31 | < 0.02 | 2.05 | |||
1058 | 100.6 | 0.13 | 19.99 | 0.06 | 0.04 | 1.52 | ||
1067 | 148.1 | 1.25 | 16.54 | 0.20 | < 0.02 | 1.54 | ||
1056 | 201.4 | 5.63 | 13.32 | 0.48 | < 0.02 | 1.21 | ||
1055 | 296.8 | 9.19 | 11.06 | 0.84 | < 0.02 | 2.19 | ||
1054 | 500 | 18.36 | 8.82 | 1.26 | < 0.02 | 5.34 | ||
1053 | 747.8 | 30.93 | 5.29 | 2.15 | < 0.02 | 31.01 | ||
1052 | 947.4 | 170.60 | 34.463 | 35.29 | 4.00 | 2.52 | < 0.02 | 63.18 |
1057 | 948.8 | 4.00 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |