Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 18
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-16 20:30 to 2007-05-16 20:46 UTC
Where:
34° 00.0' S
114° 27.4' E
to
34° 00.0' S
114° 27.4' E
Maximum Depth (m): 282
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1069 | 1.2 | 21.18 | ||||||
1068 | 1.8 | 21.17 | ||||||
1070 | 2 | 21.18 | ||||||
1065 | 2.4 | 0.37 | 21.17 | 0.08 | 0.31 | 2.21 | ||
1066 | 2.5 | 21.18 | ||||||
1063 | 23.3 | 0.37 | 21.19 | 0.07 | 0.30 | 2.19 | ||
1064 | 23.4 | 229.20 | 35.779 | 21.19 | ||||
1062 | 49.1 | 0.69 | 21.19 | 0.08 | 0.30 | 2.17 | ||
1061 | 49.3 | 21.19 | ||||||
1059 | 67.3 | 21.19 | ||||||
1060 | 67.5 | 21.20 | ||||||
1067 | 68.4 | 21.19 | ||||||
1058 | 68.6 | 21.19 | ||||||
1056 | 99.1 | 0.34 | 20.97 | 0.07 | 0.22 | 2.11 | ||
1055 | 123.4 | 20.91 | 0.09 | 0.29 | 2.15 | |||
1054 | 148.5 | 0.90 | 20.63 | 0.11 | 0.51 | 2.10 | ||
1053 | 196.6 | 0.96 | 19.56 | 0.12 | 0.19 | 2.02 | ||
1052 | 279.8 | 245.70 | 35.281 | 5.90 | 13.44 | 0.47 | 0.08 | 1.35 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |