Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 15
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-16 07:02 to 2007-05-16 08:11 UTC
Where:
34° 00.0' S
113° 46.1' E
to
34° 00.0' S
113° 46.1' E
Maximum Depth (m): 1502
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1068 | 0.3 | 21.12 | ||||||
1069 | 0.5 | 21.11 | ||||||
1070 | 0.9 | 21.11 | ||||||
1066 | 7.5 | 0.34 | 21.12 | 0.08 | 0.33 | 2.23 | ||
1065 | 24.4 | 221.90 | 35.793 | 0.33 | 21.13 | 0.07 | 0.40 | 2.29 |
1064 | 51.9 | 0.02 | 20.43 | 0.05 | 0.14 | 1.93 | ||
1062 | 51.9 | 20.43 | ||||||
1063 | 52.1 | 0.07 | 20.43 | 0.09 | 0.14 | 1.90 | ||
1061 | 71.6 | 19.85 | ||||||
1060 | 72 | 0.03 | 19.84 | 0.07 | 0.12 | 1.69 | ||
1059 | 98.5 | 0.09 | 19.52 | 0.08 | 0.21 | 1.97 | ||
1058 | 124.8 | 0.09 | 18.81 | 0.09 | 0.22 | 1.36 | ||
1067 | 150 | 0.68 | 16.92 | 0.16 | 0.33 | 1.19 | ||
1056 | 199.4 | 4.67 | 14.00 | 0.44 | 0.11 | 1.00 | ||
1055 | 299.8 | 10.77 | 11.34 | 0.85 | 0.06 | 1.75 | ||
1054 | 499.4 | 16.88 | 9.29 | 1.28 | 0.09 | 4.19 | ||
1053 | 996.9 | 33.87 | 3.96 | 2.60 | 0.08 | |||
1052 | 1501 | 162.60 | 34.579 | 35.66 | 2.93 | 2.78 | 0.16 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |