Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-11 22:23 to 2007-05-11 22:28 UTC
Where:
31° 46.0' S
115° 37.1' E
to
31° 46.0' S
115° 37.1' E
Maximum Depth (m): 28
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1058 | 0.2 | 20.68 | ||||||
1059 | 0.8 | 225.60 | 35.800 | 0.20 | 20.67 | 0.11 | < 0.02 | 1.38 |
1056 | 8.2 | 0.23 | 20.71 | 0.11 | < 0.02 | 1.36 | ||
1067 | 8.7 | 20.72 | ||||||
1055 | 17.2 | 20.65 | ||||||
1054 | 17.8 | 0.50 | 20.67 | 0.23 | 0.04 | 1.39 | ||
1052 | 26.6 | 217.70 | 35.881 | 1.02 | 20.40 | 0.16 | 0.04 | 1.36 |
1053 | 26.8 | 20.39 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |