Deployment Details
Survey: - SS200401 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Operation No.: 1
Gear: CTD 20 - SN 0552,Conductivity CTD 20-SN 2594,Fluorometer CTD 20-Chelsea 88221,Licor CTD 20-SN 4059,Oxygen CTD 20-Becman 527,Pressure CTD 20-SN 75638,Temperature CTD 20-SN 2466
When: 2004-01-21 07:01 to 2004-01-21 07:05 UTC
Where: 31° 36.9' S 115° 22.0' E
Maximum Depth (m): 31
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Nitrate (µM) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|
Unknown | 4 | 0.18 | 0.08 | < 0.02 | < 0.02 | 1.04 |
Unknown | 5 | 0.19 | 0.12 | < 0.02 | < 0.02 | 1.24 |
Unknown | 10 | 0.28 | 0.10 | < 0.02 | < 0.02 | 1.14 |
Unknown | 20 | 0.22 | 0.09 | < 0.02 | < 0.02 | 1.01 |
Unknown | 31 | 0.27 | 0.12 | < 0.02 | < 0.02 | 1.14 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 2594 | Seabird | SBE-4 | 2594 | |
Fluorometer CTD 20-Chelsea 88221 | Chelsea | 88221 | Fluorescence (arbitrary units) | |
Licor CTD 20-SN 4059 | 4059 | PAR (uE/m**2/sec) | ||
Oxygen CTD 20-Becman 527 | Seabird | Beckman | 130527 | Oxygen (µM) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Temperature CTD 20-SN 2466 | Seabird | SBE-3 | 2466 | Temperature (deg C) |