Deployment Details
Survey: - IN2025_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CDOM CTD 22 - SN 4367,CTD 22 - SN 1039,Chlorophyll - CTD 22 - Wetlabs ECO,Conductivity CTD 22 - SN 4664,Licor - CTD 22 - SN 70562,Oxygen CTD 22-SBE 43-SN 3198,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 6285,Transmissometer - CTD 22 -CST-1735DR
When: 2025-03-26 07:11 to 2025-03-26 07:52 UTC
Where: 44° 13.4' S 147° 11.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 999.8 | 193.02 | 34.423 | 30.59 | 5.17 | 2.12 | < 0.02 | 0.02 | 37.16 |
| 35 | 1000.2 | 193.11 | 34.422 | 30.64 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.17 |
| 34 | 1000 | 193.56 | 34.423 | 30.69 | 5.17 | 2.12 | 0.02 | 0.03 | 37.16 |
| 33 | 1000 | 193.07 | 34.423 | 30.68 | 5.17 | 2.13 | < 0.02 | 0.03 | 37.29 |
| 32 | 999.7 | 192.80 | 34.424 | 30.67 | 5.17 | 2.13 | < 0.02 | 0.03 | 37.20 |
| 31 | 999.4 | 192.53 | 34.423 | 30.67 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.28 |
| 30 | 999.6 | 192.44 | 34.423 | 30.62 | 5.17 | 2.13 | 0.03 | < 0.02 | 37.22 |
| 29 | 999.8 | 192.53 | 34.423 | 30.60 | 5.17 | 2.12 | < 0.02 | < 0.02 | 37.20 |
| 28 | 999.8 | 192.49 | 34.424 | 30.68 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.27 |
| 27 | 1000 | 192.62 | 34.424 | 30.67 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.26 |
| 26 | 1000.3 | 192.89 | 34.423 | 30.68 | 5.17 | 2.13 | 0.02 | 0.02 | 37.31 |
| 25 | 1000.1 | 192.40 | 34.424 | 30.68 | 5.17 | 2.13 | 0.04 | 0.02 | 37.25 |
| 24 | 999.6 | 192.53 | 34.423 | 30.69 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.28 |
| 23 | 999.7 | 192.58 | 34.424 | 30.74 | 5.17 | 2.13 | 0.03 | 0.03 | 37.30 |
| 22 | 1000.1 | 192.62 | 34.424 | 30.71 | 5.17 | 2.13 | 0.02 | 0.02 | 37.28 |
| 21 | 1000.1 | 192.58 | 34.423 | 30.76 | 5.17 | 2.12 | 0.03 | 0.02 | 37.28 |
| 20 | 999.9 | 192.67 | 34.423 | 30.75 | 5.17 | 2.13 | < 0.02 | 0.03 | 37.28 |
| 19 | 999.8 | 192.58 | 34.423 | 30.74 | 5.17 | 2.13 | 0.02 | 0.02 | 37.34 |
| 18 | 999.8 | 192.44 | 34.423 | 30.65 | 5.17 | 2.12 | 0.02 | 0.02 | 37.36 |
| 17 | 999.7 | 192.49 | 34.423 | 30.65 | 5.17 | 2.13 | 0.08 | 0.02 | 37.36 |
| 16 | 999.8 | 192.53 | 34.423 | 30.69 | 5.17 | 2.13 | 0.05 | 0.02 | 37.28 |
| 15 | 999.7 | 192.40 | 34.424 | 30.68 | 5.17 | 2.13 | 0.06 | 0.02 | 37.25 |
| 14 | 1000 | 192.40 | 34.423 | 30.70 | 5.17 | 2.13 | 0.03 | 0.02 | 37.29 |
| 13 | 1000.4 | 192.31 | 34.424 | 30.71 | 5.17 | 2.13 | 0.05 | 0.02 | 37.25 |
| 12 | 1000.1 | 192.67 | 34.424 | 30.74 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.23 |
| 11 | 999.9 | 192.58 | 34.423 | 30.74 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.10 |
| 10 | 999.9 | 192.80 | 34.423 | 30.73 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.16 |
| 9 | 999.7 | 192.62 | 34.423 | 30.69 | 5.17 | 2.13 | 0.02 | < 0.02 | 37.11 |
| 8 | 999.7 | 192.13 | 34.423 | 30.68 | 5.17 | 2.12 | < 0.02 | 0.02 | 37.09 |
| 7 | 999.9 | 192.62 | 34.423 | 30.69 | 5.17 | 2.13 | < 0.02 | < 0.02 | 37.13 |
| 6 | 1000 | 192.44 | 34.423 | 30.71 | 5.17 | 2.13 | < 0.02 | < 0.02 | 37.13 |
| 5 | 1000 | 192.49 | 34.423 | 30.82 | 5.17 | 2.13 | 0.04 | 0.02 | 37.07 |
| 4 | 1000.1 | 192.67 | 34.423 | 30.72 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.09 |
| 3 | 1000 | 192.27 | 34.423 | 30.77 | 5.17 | 2.13 | 0.02 | 0.02 | 37.09 |
| 2 | 1000.1 | 192.71 | 34.423 | 30.76 | 5.17 | 2.13 | < 0.02 | 0.02 | 37.04 |
| 1 | 999.8 | 192.35 | 34.423 | 31.06 | 5.17 | 2.13 | 0.12 | 0.02 | 37.03 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 22 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Chlorophyll - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 22 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 22 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 22-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 6285 | Seabird | SBE3P | 6285 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |