Deployment Details
Survey: - IN2026_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-2009DR
When: 2026-01-21 15:29 to 2026-01-21 18:10 UTC
Where: 64° 34.2' S 146° 39.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 5.5 | 352.29 | 33.529 | 27.41 | 0.98 | 1.84 | 0.46 | 0.28 | 35.40 |
| 28 | 39.9 | < 0.02 | < 0.02 | < 0.02 | -0.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 40 | 355.01 | 33.974 | 28.60 | -0.94 | 1.92 | 0.11 | 0.14 | 39.86 |
| 26 | 69.9 | < 0.02 | < 0.02 | < 0.02 | 1.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 70 | < 0.02 | < 0.02 | < 0.02 | 1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 69.9 | < 0.02 | < 0.02 | < 0.02 | 1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 70 | < 0.02 | < 0.02 | < 0.02 | 1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 70 | 221.47 | 34.416 | 34.64 | 1.02 | 2.38 | 0.05 | 0.13 | 69.53 |
| 21 | 100.1 | 190.52 | 34.530 | 35.21 | 1.69 | 2.40 | < 0.02 | 0.03 | 77.22 |
| 20 | 120.5 | < 0.02 | < 0.02 | < 0.02 | 1.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 120.5 | 185.66 | 34.569 | 35.11 | 1.85 | 2.40 | < 0.02 | < 0.02 | 79.57 |
| 18 | 251.3 | 181.90 | 34.673 | 33.61 | 2.01 | 2.30 | < 0.02 | < 0.02 | 84.27 |
| 17 | 500.4 | < 0.02 | < 0.02 | < 0.02 | 1.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 500.5 | < 0.02 | < 0.02 | < 0.02 | 1.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 500.5 | 195.44 | 34.717 | 32.22 | 1.71 | 2.21 | < 0.02 | < 0.02 | 90.06 |
| 14 | 1000.6 | < 0.02 | < 0.02 | < 0.02 | 1.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 1.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1000.4 | 205.75 | 34.731 | 31.79 | 1.33 | 2.18 | < 0.02 | < 0.02 | 102.31 |
| 10 | 1500.8 | 211.11 | 34.713 | 32.39 | 0.93 | 2.23 | < 0.02 | < 0.02 | 114.70 |
| 9 | 2001.3 | < 0.02 | < 0.02 | < 0.02 | 0.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 2001.3 | < 0.02 | < 0.02 | < 0.02 | 0.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 2001.3 | 217.41 | 34.693 | 32.96 | 0.55 | 2.27 | < 0.02 | < 0.02 | 123.50 |
| 6 | 3001 | < 0.02 | < 0.02 | < 0.02 | 0.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 3000.7 | < 0.02 | < 0.02 | < 0.02 | 0.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 3000.7 | 231.61 | 34.673 | 32.85 | 0.09 | 2.27 | < 0.02 | < 0.02 | 121.05 |
| 3 | 3558.9 | < 0.02 | < 0.02 | < 0.02 | -0.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 3559 | < 0.02 | < 0.02 | < 0.02 | -0.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3559.2 | 247.06 | 34.657 | 32.44 | -0.26 | 2.25 | < 0.02 | < 0.02 | 110.04 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |