Deployment Details
Survey: - IN2026_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24-SN 3168,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 4188,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-2009DR
When: 2026-01-13 04:42 to 2026-01-13 07:59 UTC
Where: 63° 30.1' S 150° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 0.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 0.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 0.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 0.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 6 | 353.58 | 33.407 | 27.47 | 0.67 | 1.91 | 0.87 | 0.28 | 37.62 |
| 31 | 49.7 | < 0.02 | < 0.02 | < 0.02 | -1.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 49.7 | 313.03 | 34.096 | 31.19 | -1.12 | 2.18 | 0.56 | 0.12 | 53.78 |
| 29 | 90.2 | < 0.02 | < 0.02 | < 0.02 | 1.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 90.5 | < 0.02 | < 0.02 | < 0.02 | 1.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 90.6 | < 0.02 | < 0.02 | < 0.02 | 1.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 90.5 | 218.08 | 34.434 | 34.67 | 1.16 | 2.39 | 0.05 | 0.15 | 71.73 |
| 25 | 100.5 | 204.28 | 34.479 | 35.03 | 1.29 | 2.41 | 0.03 | 0.12 | 74.54 |
| 24 | 160.5 | < 0.02 | < 0.02 | < 0.02 | 1.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 160.5 | < 0.02 | < 0.02 | < 0.02 | 1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 160.4 | 183.87 | 34.585 | 34.93 | 1.81 | 2.39 | < 0.02 | < 0.02 | 81.11 |
| 21 | 250.2 | < 0.02 | < 0.02 | < 0.02 | 1.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 250.2 | 181.55 | 34.644 | 34.18 | 1.91 | 2.34 | < 0.02 | < 0.02 | 84.41 |
| 19 | 502.2 | < 0.02 | < 0.02 | < 0.02 | 1.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 502.4 | < 0.02 | < 0.02 | < 0.02 | 1.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 502.3 | 190.43 | 34.718 | 32.44 | 1.86 | 2.23 | < 0.02 | < 0.02 | 88.51 |
| 16 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 1000.2 | < 0.02 | < 0.02 | < 0.02 | 1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 1000.3 | 203.21 | 34.734 | 31.68 | 1.46 | 2.19 | < 0.02 | < 0.02 | 99.27 |
| 12 | 1499.6 | < 0.02 | < 0.02 | < 0.02 | 1.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1499.9 | 209.50 | 34.719 | 32.18 | 1.05 | 2.23 | < 0.02 | < 0.02 | 110.98 |
| 10 | 2000.4 | < 0.02 | < 0.02 | < 0.02 | 0.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 2000.3 | < 0.02 | < 0.02 | < 0.02 | 0.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 2000.4 | 215.53 | 34.703 | 32.84 | 0.69 | 2.27 | 0.02 | < 0.02 | 122.00 |
| 7 | 3001.3 | < 0.02 | < 0.02 | < 0.02 | 0.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 3001.2 | < 0.02 | < 0.02 | < 0.02 | 0.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 3001.3 | 227.82 | 34.676 | 33.05 | 0.20 | 2.29 | < 0.02 | < 0.02 | 130.73 |
| 4 | 3767 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3767.1 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 3767.1 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3766.9 | 240.72 | 34.666 | 32.64 | -0.11 | 2.27 | < 0.02 | < 0.02 | 117.44 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24-SN 3168 | Seabird | SBE4C | 3168 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 4188 | Seabird | SBE43 | 4188 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |