Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 24 - SN 1332,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6024
When: 2025-08-26 20:07 to 2025-08-26 21:36 UTC
Where: 20° 32.9' S 175° 22.4' W
Maximum Depth (m): 520.6
CTD data is not currently available.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 21 | 2.6 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 3 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 23.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 20.3 | < 0.02 | < 0.02 | < 0.02 | 23.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 20.5 | 224.38 | 35.605 | 0.06 | 23.74 | 0.03 | < 0.02 | 0.02 | 0.33 |
| 12 | 68.2 | < 0.02 | < 0.02 | < 0.02 | 23.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 68.2 | < 0.02 | < 0.02 | < 0.02 | 23.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 68.3 | 215.53 | 35.639 | 0.07 | 23.40 | 0.04 | < 0.02 | 0.02 | 0.35 |
| 8 | 200.1 | < 0.02 | < 0.02 | < 0.02 | 20.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 200.2 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 200.3 | 184.32 | 35.615 | 3.64 | 20.49 | 0.32 | < 0.02 | 0.04 | 7.61 |
| 4 | 297.3 | 182.71 | 35.467 | 5.53 | 18.80 | 0.45 | < 0.02 | 0.06 | 51.56 |
| 5 | 297.4 | < 0.02 | < 0.02 | < 0.02 | 18.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 297.5 | < 0.02 | < 0.02 | < 0.02 | 18.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 520.5 | < 0.02 | < 0.02 | < 0.02 | 18.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 520.5 | 184.18 | 35.469 | 5.53 | 18.78 | 0.44 | < 0.02 | 0.05 | 45.97 |
| 3 | 520.6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 74680 | Salinity (psu) |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Temperature CTD 24 - SN 6024 | Seabird | SBE3T | 6024 | Temperature (deg C) |