Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 84
Gear: Autosal Salinometer,CTD 24 - SN 1332,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6285
When: 2024-12-07 05:39 to 2024-12-07 06:27 UTC
Where: 40° 17.7' S 148° 54.7' E
Maximum Depth (m): 578.9
CTD data is not currently available.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 32 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 4 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.1 | 258.63 | 35.513 | < 0.02 | 18.13 | 0.13 | < 0.02 | < 0.02 | 0.15 |
| 30 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 119.8 | < 0.02 | < 0.02 | < 0.02 | 14.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 119.8 | < 0.02 | < 0.02 | < 0.02 | 14.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 120 | < 0.02 | < 0.02 | < 0.02 | 14.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 120 | < 0.02 | < 0.02 | < 0.02 | 14.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 120 | 231.66 | 35.428 | 6.38 | 14.51 | 0.55 | < 0.02 | 0.11 | 2.44 |
| 21 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 14.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 14.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 14.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 120.3 | < 0.02 | < 0.02 | < 0.02 | 14.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 359.9 | < 0.02 | < 0.02 | < 0.02 | 11.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 359.9 | < 0.02 | < 0.02 | < 0.02 | 11.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 360 | < 0.02 | < 0.02 | < 0.02 | 11.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 360.1 | < 0.02 | < 0.02 | < 0.02 | 11.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 360.1 | < 0.02 | < 0.02 | < 0.02 | 11.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 360.2 | < 0.02 | < 0.02 | < 0.02 | 11.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 360.2 | < 0.02 | < 0.02 | < 0.02 | 11.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 360.3 | 224.56 | 35.045 | 13.19 | 11.64 | 0.97 | < 0.02 | < 0.02 | 4.91 |
| 10 | 360.4 | < 0.02 | < 0.02 | < 0.02 | 11.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 578.6 | < 0.02 | < 0.02 | < 0.02 | 8.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 578.6 | < 0.02 | < 0.02 | < 0.02 | 8.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 578.7 | < 0.02 | < 0.02 | < 0.02 | 8.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 578.8 | < 0.02 | < 0.02 | < 0.02 | 8.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 578.9 | < 0.02 | < 0.02 | < 0.02 | 8.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 578.9 | < 0.02 | < 0.02 | < 0.02 | 8.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 578.9 | < 0.02 | < 0.02 | < 0.02 | 8.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 578.9 | 213.12 | 34.643 | 21.50 | 8.69 | 1.49 | < 0.02 | < 0.02 | 11.44 |
| 9 | 578.9 | < 0.02 | < 0.02 | < 0.02 | 8.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72089 | Salinity (psu) |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |