Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 72
Gear: Autosal Salinometer,CTD 24 - SN 1332,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6285
When: 2024-12-04 00:54 to 2024-12-04 01:45 UTC
Where: 38° 18.7' S 149° 06.8' E
Maximum Depth (m): 559.4
CTD data is not currently available.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 17.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 17.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4 | < 0.02 | < 0.02 | < 0.02 | 17.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4 | 258.68 | 35.496 | < 0.02 | 17.58 | 0.15 | < 0.02 | < 0.02 | 0.22 |
| 32 | 4 | < 0.02 | < 0.02 | < 0.02 | 17.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 17.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 17.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 17.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 99.7 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 99.7 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 100 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 100 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 14.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 100.5 | 228.26 | 35.404 | 7.44 | 14.16 | 0.61 | < 0.02 | 0.03 | 2.76 |
| 17 | 250 | < 0.02 | < 0.02 | < 0.02 | 12.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 250 | < 0.02 | < 0.02 | < 0.02 | 12.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 250.2 | < 0.02 | < 0.02 | < 0.02 | 12.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 250.2 | < 0.02 | < 0.02 | < 0.02 | 12.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 250.3 | < 0.02 | < 0.02 | < 0.02 | 12.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 250.3 | 244.70 | 35.139 | 10.22 | 12.06 | 0.78 | < 0.02 | < 0.02 | 3.22 |
| 9 | 400.3 | < 0.02 | < 0.02 | < 0.02 | 10.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 400.4 | 224.87 | 34.864 | 16.09 | 10.42 | 1.14 | < 0.02 | 0.03 | 6.07 |
| 13 | 400.4 | < 0.02 | < 0.02 | < 0.02 | 10.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 400.5 | < 0.02 | < 0.02 | < 0.02 | 10.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 400.7 | < 0.02 | < 0.02 | < 0.02 | 10.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 400.8 | < 0.02 | < 0.02 | < 0.02 | 10.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 558.9 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 559 | 213.88 | 34.635 | 21.63 | 8.60 | 1.50 | < 0.02 | < 0.02 | 11.53 |
| 7 | 559.1 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 559.1 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 559.1 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 559.2 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 559.2 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 559.4 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72089 | Salinity (psu) |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |