Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CDOM CTD 22 - SN 4367,CTD 22 - SN 1039,Chlorophyll - CTD 22 - Wetlabs ECO,Conductivity CTD 22 - SN 4664,Licor - CTD 22 - SN 70562,Oxygen CTD 22-SBE 43-SN 3198,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 6285,Transmissometer - CTD 22 -CST-1735DR
When: 2025-03-10 06:44 to 2025-03-10 08:49 UTC
Where: 38° 37.9' S 149° 02.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 26 | 5.9 | 234.51 | 35.580 | 0.07 | 20.55 | 0.10 | < 0.02 | < 0.02 | 0.66 |
| 32 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 20.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 20.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 6 | < 0.02 | < 0.02 | < 0.02 | 20.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6 | < 0.02 | < 0.02 | < 0.02 | 20.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 20.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 20.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 20.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 20.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 20.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 20.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 40.6 | 216.20 | 35.532 | 2.55 | 18.02 | 0.31 | 0.03 | 0.33 | 1.15 |
| 24 | 59.8 | 202.36 | 35.482 | 6.55 | 16.57 | 0.53 | < 0.02 | 0.07 | 2.00 |
| 22 | 150.3 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 150.4 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 150.5 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 150.5 | 211.38 | 35.256 | 10.73 | 13.56 | 0.80 | < 0.02 | < 0.02 | 3.62 |
| 16 | 250.8 | 215.49 | 35.044 | 13.82 | 11.82 | 0.99 | < 0.02 | < 0.02 | 4.76 |
| 17 | 250.9 | < 0.02 | < 0.02 | < 0.02 | 11.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 250.9 | < 0.02 | < 0.02 | < 0.02 | 11.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 251 | < 0.02 | < 0.02 | < 0.02 | 11.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 501.1 | < 0.02 | < 0.02 | < 0.02 | 8.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 501.2 | 215.53 | 34.622 | 21.39 | 8.78 | 1.46 | < 0.02 | < 0.02 | 9.32 |
| 15 | 501.4 | < 0.02 | < 0.02 | < 0.02 | 8.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 501.4 | < 0.02 | < 0.02 | < 0.02 | 8.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 900.5 | < 0.02 | < 0.02 | < 0.02 | 5.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 901.2 | < 0.02 | < 0.02 | < 0.02 | 5.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 901.6 | < 0.02 | < 0.02 | < 0.02 | 5.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 902.3 | 192.80 | 34.435 | 31.04 | 5.28 | 2.12 | < 0.02 | < 0.02 | 38.02 |
| 7 | 1500.7 | 160.47 | 34.587 | 36.00 | 2.92 | 2.49 | < 0.02 | < 0.02 | 89.16 |
| 6 | 1999.8 | 176.32 | 34.681 | 34.01 | 2.27 | 2.35 | < 0.02 | < 0.02 | 92.66 |
| 5 | 2500.6 | 190.17 | 34.725 | 33.04 | 1.89 | 2.28 | < 0.02 | < 0.02 | 99.99 |
| 3 | 3047.5 | < 0.02 | < 0.02 | < 0.02 | 1.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 3047.6 | < 0.02 | < 0.02 | < 0.02 | 1.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 3047.9 | < 0.02 | < 0.02 | < 0.02 | 1.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3048 | 195.48 | 34.724 | 33.20 | 1.55 | 2.28 | < 0.02 | < 0.02 | 108.98 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 74680 | Salinity (psu) |
| CDOM CTD 22 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Chlorophyll - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 22 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 22 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 22-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 6285 | Seabird | SBE3P | 6285 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |