Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CDOM CTD 22 - SN 4367,CTD 22 - SN 1039,Chlorophyll - CTD 22 - Wetlabs ECO,Conductivity CTD 22 - SN 4664,Licor - CTD 22 - SN 70562,Oxygen CTD 22-SBE 43-SN 3198,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 6285,Transmissometer - CTD 22 -CST-1735DR
When: 2025-03-08 21:15 to 2025-03-08 22:19 UTC
Where: 42° 53.0' S 148° 25.7' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 26 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 5.6 | 238.85 | 35.641 | < 0.02 | 18.75 | 0.12 | < 0.02 | < 0.02 | 0.23 |
| 32 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 18.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 60.1 | 249.57 | 35.174 | 0.87 | 15.84 | 0.27 | 0.50 | 0.06 | 0.64 |
| 14 | 60.3 | < 0.02 | < 0.02 | < 0.02 | 15.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 100.3 | 208.03 | 35.386 | 8.78 | 14.95 | 0.68 | < 0.02 | < 0.02 | 2.80 |
| 12 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 14.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 199.8 | 223.89 | 35.173 | 11.25 | 12.72 | 0.84 | 0.03 | < 0.02 | 3.60 |
| 10 | 199.9 | < 0.02 | < 0.02 | < 0.02 | 12.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 301.1 | 219.11 | 34.959 | 14.85 | 11.22 | 1.08 | < 0.02 | < 0.02 | 5.04 |
| 8 | 301.4 | < 0.02 | < 0.02 | < 0.02 | 11.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 399.4 | 217.23 | 34.748 | 18.44 | 9.82 | 1.31 | < 0.02 | < 0.02 | 6.75 |
| 6 | 399.9 | < 0.02 | < 0.02 | < 0.02 | 9.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 502 | 220.18 | 34.621 | 20.83 | 8.80 | 1.47 | < 0.02 | < 0.02 | 8.80 |
| 4 | 502 | < 0.02 | < 0.02 | < 0.02 | 8.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1252.9 | 170.52 | 34.501 | 34.35 | 3.56 | 2.44 | < 0.02 | < 0.02 | 69.85 |
| 1 | 1253 | < 0.02 | < 0.02 | < 0.02 | 3.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 74680 | Salinity (psu) |
| CDOM CTD 22 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Chlorophyll - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 22 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 22 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 22-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 6285 | Seabird | SBE3P | 6285 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |