Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CDOM CTD 22 - SN 4367,CTD 22 - SN 1039,Chlorophyll - CTD 22 - Wetlabs ECO,Conductivity CTD 22 - SN 4664,Licor - CTD 22 - SN 70562,Oxygen CTD 22-SBE 43-SN 3198,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - Wetlabs ECO,Temperature CTD 22 - SN 6285,Transmissometer - CTD 22 -CST-1735DR
When: 2025-03-08 05:58 to 2025-03-08 06:38 UTC
Where: 43° 11.4' S 148° 17.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 5 | 1002.9 | 187.62 | 34.430 | 32.60 | 4.72 | 2.22 | < 0.02 | < 0.02 | 44.49 |
| 6 | 1003 | 187.67 | 34.432 | 32.23 | 4.72 | 2.22 | < 0.02 | < 0.02 | 44.51 |
| 2 | 1003.1 | 188.16 | 34.430 | 32.38 | 4.72 | 2.21 | < 0.02 | < 0.02 | 44.42 |
| 4 | 1003.1 | 187.58 | 34.431 | 32.12 | 4.72 | 2.21 | < 0.02 | < 0.02 | 44.56 |
| 15 | 1003.1 | 188.07 | 34.431 | 32.25 | 4.71 | 2.21 | < 0.02 | < 0.02 | 44.94 |
| 3 | 1003.2 | 187.67 | 34.431 | 32.24 | 4.72 | 2.20 | < 0.02 | < 0.02 | 44.44 |
| 22 | 1003.2 | 187.67 | 34.432 | 32.33 | 4.72 | 2.21 | < 0.02 | < 0.02 | 45.07 |
| 14 | 1003.2 | 187.80 | 34.431 | 32.12 | 4.71 | 2.22 | < 0.02 | < 0.02 | 44.81 |
| 1 | 1003.2 | 187.71 | 34.432 | 32.21 | 4.72 | 2.21 | < 0.02 | < 0.02 | 44.55 |
| 11 | 1003.3 | 187.80 | 34.431 | 32.05 | 4.71 | 2.22 | < 0.02 | < 0.02 | 44.56 |
| 7 | 1003.3 | 187.80 | 34.430 | 32.13 | 4.72 | 2.22 | < 0.02 | < 0.02 | 44.49 |
| 10 | 1003.3 | 188.20 | 34.431 | 32.46 | 4.71 | 2.22 | < 0.02 | < 0.02 | 44.45 |
| 21 | 1003.3 | 191.06 | 34.433 | 32.33 | 4.71 | 2.20 | < 0.02 | < 0.02 | 45.13 |
| 16 | 1003.4 | 190.03 | 34.432 | 32.22 | 4.71 | 2.21 | < 0.02 | < 0.02 | 44.95 |
| 12 | 1003.4 | 188.07 | 34.431 | 32.08 | 4.71 | 2.22 | < 0.02 | < 0.02 | 44.71 |
| 9 | 1003.5 | 188.51 | 34.430 | 32.20 | 4.71 | 2.23 | < 0.02 | < 0.02 | 44.51 |
| 13 | 1003.5 | 187.80 | 34.431 | 32.22 | 4.71 | 2.22 | < 0.02 | < 0.02 | 44.79 |
| 23 | 1003.5 | 187.40 | 34.432 | 32.32 | 4.71 | 2.21 | < 0.02 | < 0.02 | 45.03 |
| 8 | 1003.5 | 188.42 | 34.430 | 32.10 | 4.71 | 2.22 | < 0.02 | < 0.02 | 44.47 |
| 20 | 1003.7 | 190.93 | 34.433 | 32.47 | 4.71 | 2.21 | < 0.02 | < 0.02 | 45.09 |
| 29 | 1003.7 | 187.26 | 34.433 | 32.41 | 4.72 | 2.22 | < 0.02 | < 0.02 | 45.28 |
| 17 | 1003.7 | 190.88 | 34.432 | 32.36 | 4.71 | 2.22 | < 0.02 | < 0.02 | 44.86 |
| 30 | 1003.8 | 187.31 | 34.432 | 32.17 | 4.71 | 2.22 | < 0.02 | < 0.02 | 45.08 |
| 18 | 1003.9 | 187.75 | 34.434 | 32.21 | 4.71 | 2.21 | < 0.02 | < 0.02 | 44.93 |
| 24 | 1004 | 188.16 | 34.432 | 32.26 | 4.71 | 2.21 | < 0.02 | < 0.02 | 45.10 |
| 19 | 1004.1 | 193.20 | 34.432 | 32.40 | 4.71 | 2.21 | < 0.02 | < 0.02 | 44.93 |
| 31 | 1004.1 | 187.08 | 34.432 | 32.24 | 4.71 | 2.21 | < 0.02 | < 0.02 | 45.04 |
| 28 | 1004.1 | 187.26 | 34.432 | 32.74 | 4.71 | 2.22 | < 0.02 | < 0.02 | 45.14 |
| 33 | 1004.2 | 187.49 | 34.432 | 32.29 | 4.71 | 2.20 | < 0.02 | < 0.02 | 44.97 |
| 34 | 1004.2 | 188.16 | 34.431 | 32.58 | 4.71 | 2.20 | < 0.02 | < 0.02 | 44.91 |
| 25 | 1004.3 | 187.67 | 34.432 | 32.36 | 4.71 | 2.22 | < 0.02 | < 0.02 | 45.11 |
| 32 | 1004.3 | 187.17 | 34.432 | 32.24 | 4.71 | 2.19 | < 0.02 | < 0.02 | 45.00 |
| 36 | 1004.4 | 188.16 | 34.431 | 32.22 | 4.70 | 2.22 | < 0.02 | < 0.02 | 44.87 |
| 35 | 1004.4 | 189.27 | 34.431 | 32.36 | 4.71 | 2.20 | < 0.02 | < 0.02 | 44.91 |
| 27 | 1004.5 | 187.31 | 34.432 | 31.99 | 4.71 | 2.22 | < 0.02 | < 0.02 | 45.09 |
| 26 | 1004.6 | 187.62 | 34.434 | 32.34 | 4.71 | 2.22 | < 0.02 | < 0.02 | 45.12 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 74680 | Salinity (psu) |
| CDOM CTD 22 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 22 - SN 1039 | Seabird | SBE9+ V1 | 1039 | |
| Chlorophyll - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 22 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 22 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 22-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1039 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| Scattering - CTD 22 - Wetlabs ECO | WET Labs | FLBBRTD | 6890 | Turbidity (%) |
| Temperature CTD 22 - SN 6285 | Seabird | SBE3P | 6285 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |