Please login if you have access to particular applications.
Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 47
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-05 02:20 to 2021-03-05 03:07 UTC
Where: 67° 59.9' S 74° 59.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.4 | < 0.02 | < 0.02 | < 0.02 | -1.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 5.4 | < 0.02 | 33.263 | 22.32 | -1.20 | 1.60 | 1.76 | 0.15 | 38.15 |
36 | 5.5 | < 0.02 | < 0.02 | < 0.02 | -1.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.5 | < 0.02 | < 0.02 | < 0.02 | -1.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 14.5 | 359.03 | 33.305 | 22.26 | -1.20 | 1.62 | 1.82 | 0.15 | 38.41 |
32 | 14.6 | < 0.02 | < 0.02 | < 0.02 | -1.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 34.9 | < 0.02 | < 0.02 | < 0.02 | -0.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 34.9 | 348.71 | 33.887 | 22.08 | -0.71 | 1.78 | 3.39 | 0.13 | 46.28 |
27 | 49.7 | 343.71 | 33.989 | 22.26 | -0.83 | 1.84 | 3.74 | 0.12 | 49.00 |
28 | 49.8 | < 0.02 | < 0.02 | < 0.02 | -0.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 60.3 | 327.81 | 34.111 | 25.84 | -1.03 | 2.03 | 3.34 | 0.16 | 53.61 |
25 | 60.3 | < 0.02 | < 0.02 | < 0.02 | -1.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 80.1 | 313.48 | 34.255 | 30.28 | -1.61 | 2.17 | 1.15 | 0.26 | 58.10 |
23 | 80.1 | < 0.02 | < 0.02 | < 0.02 | -1.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 150.7 | < 0.02 | < 0.02 | < 0.02 | -1.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 150.8 | 315.84 | 34.348 | 31.20 | -1.61 | 2.19 | 0.63 | 0.23 | 61.78 |
18 | 236.3 | < 0.02 | < 0.02 | < 0.02 | -1.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 236.5 | < 0.02 | < 0.02 | < 0.02 | -1.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 236.6 | 320.44 | 34.426 | 31.27 | -1.70 | 2.16 | < 0.02 | 0.03 | 64.06 |
16 | 350.3 | 326.16 | 34.467 | 31.05 | -1.80 | 2.14 | < 0.02 | 0.03 | 63.78 |
17 | 350.4 | < 0.02 | < 0.02 | < 0.02 | -1.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 399.9 | < 0.02 | < 0.02 | < 0.02 | -1.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 399.9 | 320.22 | 34.490 | 31.35 | -1.76 | 2.16 | < 0.02 | 0.03 | 66.38 |
10 | 450.6 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 450.7 | 319.24 | 34.521 | 31.62 | -1.87 | 2.20 | < 0.02 | 0.04 | 71.07 |
11 | 450.7 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 450.7 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 474.7 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 474.7 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 498.8 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 498.8 | < 0.02 | < 0.02 | < 0.02 | -1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 498.8 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 498.8 | < 0.02 | < 0.02 | < 0.02 | -1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 498.8 | 317.54 | 34.533 | 31.84 | -1.89 | 2.21 | < 0.02 | 0.07 | 76.17 |
8 | 498.8 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 498.8 | < 0.02 | < 0.02 | < 0.02 | -1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |