Please login if you have access to particular applications.
Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 43
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-02 18:55 to 2021-03-02 21:16 UTC
Where: 65° 20.0' S 70° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.5 | 344.51 | 33.747 | 28.08 | -0.54 | 1.86 | 0.08 | 0.23 | 53.66 |
35 | 5.6 | < 0.02 | < 0.02 | < 0.02 | -0.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 15.2 | 344.43 | 33.746 | 28.07 | -0.54 | 1.87 | 0.09 | 0.23 | 53.59 |
32 | 28.5 | 340.36 | 33.810 | 28.45 | -0.55 | 1.89 | 0.09 | 0.21 | 55.01 |
33 | 28.6 | < 0.02 | < 0.02 | < 0.02 | -0.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 50.2 | 308.43 | 34.198 | 30.63 | -1.29 | 2.10 | 0.16 | 0.14 | 67.50 |
29 | 65.5 | < 0.02 | < 0.02 | < 0.02 | -1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 65.6 | 299.32 | 34.284 | 31.30 | -1.52 | 2.15 | 0.10 | 0.14 | 70.36 |
28 | 90.4 | 283.24 | < 0.02 | 32.25 | -1.39 | 2.22 | < 0.02 | 0.19 | 73.99 |
27 | 150.8 | 229.65 | 34.578 | 32.83 | 0.26 | 2.26 | < 0.02 | 0.03 | 88.95 |
26 | 200.2 | 220.27 | 34.646 | 32.66 | 0.63 | 2.26 | < 0.02 | 0.03 | 93.36 |
24 | 280.2 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 280.3 | 214.15 | 34.684 | 32.47 | 0.89 | 2.25 | < 0.02 | 0.02 | 98.23 |
21 | 400.8 | 215.27 | 34.690 | 32.43 | 0.82 | 2.25 | < 0.02 | 0.02 | 102.19 |
22 | 400.9 | < 0.02 | < 0.02 | < 0.02 | 0.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 400.9 | < 0.02 | < 0.02 | < 0.02 | 0.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 649.6 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 649.7 | 218.08 | 34.688 | 32.67 | 0.66 | 2.26 | < 0.02 | 0.02 | 108.92 |
19 | 649.7 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 900.3 | 219.69 | 34.682 | 32.95 | 0.49 | 2.29 | < 0.02 | 0.02 | 114.79 |
17 | 900.4 | < 0.02 | < 0.02 | < 0.02 | 0.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1150.6 | 217.32 | 34.686 | 33.37 | 0.43 | 2.31 | < 0.02 | < 0.02 | 123.48 |
15 | 1150.7 | < 0.02 | < 0.02 | < 0.02 | 0.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1500.4 | 222.23 | 34.678 | 33.48 | 0.25 | 2.32 | < 0.02 | < 0.02 | 126.88 |
13 | 1500.5 | < 0.02 | < 0.02 | < 0.02 | 0.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 1900.5 | 228.80 | 34.670 | 33.34 | 0.08 | 2.31 | < 0.02 | < 0.02 | 128.70 |
10 | 2300.3 | 233.62 | 34.665 | 33.38 | -0.02 | 2.31 | < 0.02 | < 0.02 | 128.07 |
8 | 2760.3 | 237.95 | 34.658 | 33.26 | -0.16 | 2.32 | < 0.02 | 0.02 | 136.79 |
9 | 2760.4 | < 0.02 | < 0.02 | < 0.02 | -0.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2766.2 | < 0.02 | < 0.02 | < 0.02 | -0.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2766.3 | < 0.02 | < 0.02 | < 0.02 | -0.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2790.3 | 239.43 | 34.651 | 33.30 | -0.24 | 2.33 | < 0.02 | 0.03 | 137.27 |
5 | 2790.3 | < 0.02 | < 0.02 | < 0.02 | -0.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2790.4 | < 0.02 | < 0.02 | < 0.02 | -0.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 2790.4 | < 0.02 | < 0.02 | < 0.02 | -0.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2790.4 | < 0.02 | < 0.02 | < 0.02 | -0.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |