Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 53
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-06-08 23:33 to 2019-06-09 00:40 UTC
Where: 19° 32.3' S 111° 26.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2028 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 5.4 | 204.46 | 34.838 | 0.08 | 26.21 | 0.08 | 0.02 | < 0.02 | 2.74 |
2031 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 6 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 9.8 | < 0.02 | < 0.02 | 0.08 | 26.21 | 0.08 | < 0.02 | < 0.02 | 2.80 |
2025 | 9.8 | 204.59 | 34.837 | 0.08 | 26.21 | 0.08 | < 0.02 | < 0.02 | 2.81 |
2022 | 24.8 | 204.46 | 34.838 | 0.08 | 26.22 | 0.08 | < 0.02 | < 0.02 | 2.80 |
2023 | 25 | < 0.02 | < 0.02 | 0.07 | 26.22 | 0.08 | 0.02 | < 0.02 | 2.92 |
2024 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 26.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 50.6 | 204.32 | 34.838 | 0.08 | 26.23 | 0.08 | < 0.02 | < 0.02 | 2.67 |
2017 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 26.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 50.7 | 204.32 | 34.837 | 0.07 | 26.23 | 0.08 | 0.02 | < 0.02 | 2.90 |
2019 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 26.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 75.6 | 185.70 | 34.791 | 1.90 | 24.93 | 0.25 | 0.02 | 0.15 | 4.97 |
2013 | 99 | 150.86 | 34.801 | 8.16 | 22.05 | 0.63 | < 0.02 | 0.03 | 9.55 |
1214 | 99.3 | < 0.02 | < 0.02 | < 0.02 | 22.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 124.9 | 178.42 | 35.245 | 4.10 | 21.43 | 0.38 | < 0.02 | 0.02 | 5.30 |
2011 | 150.2 | 179.45 | 35.416 | 4.92 | 20.34 | 0.41 | < 0.02 | 0.02 | 5.66 |
2010 | 199.7 | 198.96 | 35.693 | 3.28 | 18.93 | 0.30 | < 0.02 | < 0.02 | 3.82 |
2009 | 250 | 215.18 | 35.757 | 2.56 | 17.29 | 0.27 | < 0.02 | < 0.02 | 2.37 |
2008 | 299.7 | 215.49 | 35.433 | 6.33 | 14.67 | 0.54 | < 0.02 | < 0.02 | 5.83 |
1201 | 330 | 194.01 | 35.136 | 12.56 | 12.93 | 0.95 | < 0.02 | < 0.02 | 12.65 |
2006 | 399.8 | 226.07 | 34.907 | 13.61 | 10.92 | 1.00 | < 0.02 | < 0.02 | 7.47 |
21 | 439.8 | 240.19 | 34.776 | 14.95 | 9.99 | 1.06 | < 0.02 | < 0.02 | 4.94 |
12004 | 500.7 | 206.87 | 34.658 | 20.90 | 8.98 | 1.45 | < 0.02 | < 0.02 | 15.13 |
12003 | 602.5 | 131.71 | 34.627 | 30.03 | 7.88 | 2.10 | < 0.02 | < 0.02 | 44.27 |
12002 | 821.8 | 95.26 | 34.633 | 36.32 | 5.92 | 2.61 | < 0.02 | < 0.02 | 77.59 |
12001 | 999.4 | 95.35 | 34.635 | 37.04 | 5.11 | 2.68 | < 0.02 | < 0.02 | 92.24 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |