Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 51
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-06-07 10:17 to 2019-06-07 11:14 UTC
Where: 15° 17.2' S 111° 10.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2031 | 6.2 | 205.75 | 34.630 | < 0.02 | 27.05 | 0.04 | < 0.02 | < 0.02 | 1.97 |
2034 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 10.1 | 205.75 | 34.629 | < 0.02 | 27.06 | 0.04 | < 0.02 | < 0.02 | 1.98 |
2030 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 25.7 | 205.80 | 34.629 | < 0.02 | 27.03 | 0.04 | < 0.02 | < 0.02 | 2.00 |
2028 | 25.8 | < 0.02 | < 0.02 | < 0.02 | 27.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 26.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 26.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 26.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 26.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 50.9 | 205.80 | 34.628 | < 0.02 | 26.98 | 0.04 | < 0.02 | < 0.02 | 2.03 |
2019 | 75.6 | 206.87 | 34.647 | < 0.02 | 26.97 | 0.04 | < 0.02 | < 0.02 | 2.10 |
2021 | 75.8 | < 0.02 | < 0.02 | < 0.02 | 26.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 75.8 | < 0.02 | < 0.02 | < 0.02 | 26.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 90.8 | < 0.02 | < 0.02 | < 0.02 | 24.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 90.9 | < 0.02 | < 0.02 | < 0.02 | 24.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 90.9 | < 0.02 | < 0.02 | < 0.02 | 24.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 90.9 | < 0.02 | < 0.02 | < 0.02 | 24.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 91 | < 0.02 | < 0.02 | < 0.02 | 24.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 91 | < 0.02 | < 0.02 | < 0.02 | 24.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 91 | 208.08 | 34.791 | 0.29 | 24.26 | 0.13 | 0.03 | 0.10 | 3.31 |
2012 | 91.1 | < 0.02 | < 0.02 | < 0.02 | 24.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 101.5 | 187.08 | 34.773 | 1.79 | 23.35 | 0.27 | < 0.02 | 0.29 | 4.77 |
2009 | 125.6 | 153.54 | 34.881 | 8.34 | 21.72 | 0.62 | < 0.02 | 0.03 | 9.36 |
2008 | 150.6 | 140.55 | 34.951 | 11.38 | 19.98 | 0.80 | 0.02 | < 0.02 | 12.84 |
1201 | 175.3 | 131.12 | 34.943 | 14.93 | 17.84 | 1.04 | < 0.02 | < 0.02 | 18.18 |
2006 | 200.6 | 151.62 | 35.201 | 12.47 | 17.07 | 0.89 | < 0.02 | < 0.02 | 15.47 |
21 | 300.2 | 144.21 | 34.936 | 19.81 | 12.20 | 1.39 | 0.02 | < 0.02 | 22.85 |
12004 | 400.3 | 172.12 | 34.755 | 22.28 | 9.89 | 1.52 | < 0.02 | < 0.02 | 20.98 |
12003 | 499.1 | 133.98 | 34.665 | 28.90 | 8.51 | 1.98 | < 0.02 | < 0.02 | 35.35 |
12002 | 770.7 | 87.09 | 34.647 | 36.59 | 6.22 | 2.62 | < 0.02 | < 0.02 | 80.25 |
12001 | 1001.8 | 93.03 | 34.632 | 37.17 | 5.08 | 2.68 | < 0.02 | < 0.02 | 98.24 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |