Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 50
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-06-06 13:41 to 2019-06-06 14:45 UTC
Where: 13° 47.0' S 111° 09.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2031 | 5.6 | 201.56 | 34.313 | 0.02 | 27.87 | 0.06 | < 0.02 | < 0.02 | 2.24 |
2034 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 27.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 27.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 27.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 27.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 10.9 | 201.69 | 34.313 | 0.02 | 27.86 | 0.06 | < 0.02 | < 0.02 | 2.24 |
2028 | 25.4 | < 0.02 | < 0.02 | < 0.02 | 27.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 25.5 | 201.60 | 34.313 | 0.02 | 27.87 | 0.05 | < 0.02 | < 0.02 | 2.20 |
2023 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 27.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 50.3 | 201.64 | 34.315 | 0.02 | 27.88 | 0.05 | < 0.02 | < 0.02 | 2.25 |
2026 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 27.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 27.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 27.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 27.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 27.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 75.5 | 204.50 | 34.560 | 0.02 | 27.44 | 0.06 | 0.06 | < 0.02 | 2.11 |
2013 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 27.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 27.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 75.6 | < 0.02 | < 0.02 | < 0.02 | 27.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 75.7 | < 0.02 | < 0.02 | < 0.02 | 27.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 75.7 | < 0.02 | < 0.02 | < 0.02 | 27.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 75.7 | < 0.02 | < 0.02 | < 0.02 | 27.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 75.8 | < 0.02 | < 0.02 | < 0.02 | 27.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 75.8 | < 0.02 | < 0.02 | < 0.02 | 27.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 100.7 | 176.28 | 34.567 | 2.79 | 24.28 | 0.34 | < 0.02 | 0.34 | 5.50 |
2009 | 126 | 171.54 | 34.756 | 4.25 | 22.84 | 0.42 | < 0.02 | 0.03 | 6.29 |
2008 | 150.2 | 142.33 | 34.798 | 10.25 | 21.17 | 0.75 | < 0.02 | 0.02 | 11.16 |
1201 | 200.5 | 132.20 | 34.959 | 15.11 | 17.27 | 1.08 | < 0.02 | < 0.02 | 18.72 |
2006 | 270.7 | 107.72 | 34.661 | 25.09 | 12.02 | 1.77 | < 0.02 | < 0.02 | 36.43 |
21 | 300.4 | 110.94 | 34.692 | 25.58 | 11.48 | 1.80 | < 0.02 | < 0.02 | 36.90 |
12004 | 400 | 125.81 | 34.699 | 26.82 | 9.86 | 1.87 | < 0.02 | < 0.02 | 36.68 |
12003 | 500.7 | 105.22 | 34.660 | 31.64 | 8.44 | 2.20 | < 0.02 | < 0.02 | 47.76 |
12002 | 721.5 | 84.14 | 34.643 | 36.16 | 6.73 | 2.59 | < 0.02 | < 0.02 | 76.41 |
12001 | 1001.9 | 93.07 | 34.619 | 37.09 | 5.20 | 2.69 | < 0.02 | < 0.02 | 98.80 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |