Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 49
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-06-06 00:22 to 2019-06-06 03:48 UTC
Where: 12° 30.0' S 110° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2033 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 27.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 27.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 27.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 27.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 4.9 | 202.05 | 34.180 | 0.02 | 27.95 | 0.06 | < 0.02 | < 0.02 | 2.39 |
2031 | 10.1 | 202.05 | 34.180 | 0.03 | 27.95 | 0.05 | < 0.02 | < 0.02 | 2.35 |
2030 | 25.1 | 201.91 | 34.179 | 0.03 | 27.94 | 0.05 | < 0.02 | < 0.02 | 2.43 |
2029 | 50.8 | 201.33 | 34.183 | 0.02 | 27.92 | 0.05 | < 0.02 | < 0.02 | 2.41 |
2022 | 64.8 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 64.9 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 64.9 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 64.9 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 65 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 65 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 65 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 65 | 200.62 | 34.183 | 0.05 | 27.90 | 0.06 | < 0.02 | < 0.02 | 2.43 |
2027 | 65.1 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 65.1 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 65.2 | < 0.02 | < 0.02 | < 0.02 | 27.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 74.9 | 174.89 | 34.227 | 2.91 | 26.32 | 0.33 | 0.02 | 0.32 | 5.52 |
2017 | 75 | < 0.02 | < 0.02 | < 0.02 | 26.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 100.3 | 139.57 | 34.343 | 9.20 | 23.82 | 0.70 | < 0.02 | 0.07 | 10.45 |
1214 | 125.2 | < 0.02 | < 0.02 | < 0.02 | 20.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 125.4 | 128.80 | 34.371 | 13.45 | 20.81 | 0.96 | < 0.02 | 0.03 | 16.31 |
2012 | 150.1 | 118.13 | 34.664 | 16.12 | 18.49 | 1.14 | < 0.02 | < 0.02 | 19.20 |
2010 | 199.9 | 112.23 | 34.684 | 20.56 | 15.11 | 1.46 | < 0.02 | < 0.02 | 27.70 |
2011 | 200 | < 0.02 | < 0.02 | < 0.02 | 15.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 300.4 | 98.88 | 34.717 | 27.36 | 10.92 | 1.91 | < 0.02 | < 0.02 | 37.54 |
2008 | 400 | 112.32 | 34.683 | 28.78 | 9.44 | 2.01 | < 0.02 | < 0.02 | 41.11 |
1201 | 500.4 | 90.53 | 34.672 | 32.62 | 8.50 | 2.29 | < 0.02 | < 0.02 | 51.39 |
2006 | 640.8 | 76.95 | 34.684 | 35.49 | 7.52 | 2.53 | < 0.02 | < 0.02 | 67.44 |
21 | 1000.5 | 92.45 | 34.616 | 36.70 | 5.31 | 2.67 | < 0.02 | < 0.02 | 98.67 |
12004 | 2000.5 | 138.18 | 34.732 | 36.22 | 2.63 | 2.60 | < 0.02 | < 0.02 | 122.03 |
12003 | 3000.5 | 171.86 | 34.725 | 34.80 | 1.68 | 2.45 | < 0.02 | < 0.02 | 129.68 |
12002 | 4001.4 | 193.38 | 34.715 | 34.09 | 1.22 | 2.37 | < 0.02 | < 0.02 | 132.71 |
12001 | 4766.2 | 200.53 | 34.712 | 33.74 | 1.17 | 2.34 | < 0.02 | < 0.02 | 130.72 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |