Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 48
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-06-05 15:32 to 2019-06-05 18:50 UTC
Where: 11° 30.0' S 110° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2132 | 3.3 | 202.00 | 34.184 | 0.03 | 28.03 | 0.06 | < 0.02 | < 0.02 | 2.07 |
2033 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 28.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 28.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 4 | < 0.02 | < 0.02 | < 0.02 | 28.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 9.9 | 201.96 | 34.183 | 0.03 | 28.03 | 0.05 | < 0.02 | < 0.02 | 2.12 |
2030 | 23.7 | 201.60 | 34.185 | 0.03 | 28.04 | 0.05 | < 0.02 | < 0.02 | 2.10 |
2029 | 49.9 | 201.33 | 34.231 | 0.04 | 28.06 | 0.05 | < 0.02 | < 0.02 | 2.15 |
2028 | 75.3 | 153.81 | 34.255 | 6.62 | 24.58 | 0.56 | < 0.02 | 0.48 | 8.73 |
2018 | 80 | < 0.02 | < 0.02 | < 0.02 | 24.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 80 | < 0.02 | < 0.02 | < 0.02 | 24.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 24.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 24.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 24.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 24.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 24.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 24.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 24.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 24.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 80.3 | < 0.02 | < 0.02 | < 0.02 | 24.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 24.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 80.4 | 149.44 | 34.237 | 7.57 | 24.28 | 0.61 | < 0.02 | 0.38 | 9.50 |
1214 | 100 | < 0.02 | < 0.02 | < 0.02 | 22.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 125.3 | 121.70 | 34.389 | 14.37 | 20.02 | 1.03 | < 0.02 | 0.03 | 17.85 |
2012 | 150.4 | 109.06 | 34.547 | 17.37 | 17.44 | 1.23 | < 0.02 | 0.02 | 22.66 |
2010 | 199.9 | 110.13 | 34.550 | 22.98 | 13.74 | 1.63 | < 0.02 | < 0.02 | 33.06 |
2011 | 200 | < 0.02 | < 0.02 | < 0.02 | 13.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 300 | 92.31 | 34.648 | 28.45 | 10.89 | 2.00 | < 0.02 | < 0.02 | 41.18 |
2008 | 400.2 | 90.75 | 34.697 | 30.64 | 9.74 | 2.12 | < 0.02 | < 0.02 | 43.40 |
1201 | 500.6 | 79.76 | 34.714 | 33.45 | 8.68 | 2.34 | < 0.02 | < 0.02 | 51.01 |
2006 | 608.1 | 75.21 | 34.695 | 35.11 | 7.83 | 2.50 | < 0.02 | < 0.02 | 63.01 |
21 | 1002.6 | 92.85 | 34.620 | 36.94 | 5.22 | 2.68 | < 0.02 | < 0.02 | 100.02 |
12004 | 2000.1 | 139.83 | 34.732 | 36.21 | 2.61 | 2.60 | < 0.02 | < 0.02 | 121.96 |
12003 | 2999.4 | 172.84 | 34.725 | 34.89 | 1.62 | 2.45 | < 0.02 | < 0.02 | 130.84 |
12002 | 4000.9 | 192.85 | 34.714 | 34.13 | 1.22 | 2.37 | < 0.02 | < 0.02 | 133.22 |
12001 | 4580.5 | 196.20 | 34.713 | 33.94 | 1.18 | 2.36 | < 0.02 | < 0.02 | 133.94 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |