Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 47
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-06-05 12:38 to 2019-06-05 13:19 UTC
Where: 11° 29.9' S 110° 00.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2033 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 28.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 28.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 28.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 28.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 28.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 5 | < 0.02 | < 0.02 | 0.02 | 28.10 | 0.06 | < 0.02 | < 0.02 | 2.01 |
2030 | 10.7 | 202.31 | 34.171 | 0.02 | 28.09 | 0.05 | < 0.02 | < 0.02 | 2.09 |
2029 | 19.2 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 20.9 | < 0.02 | < 0.02 | 0.02 | 28.06 | 0.05 | < 0.02 | < 0.02 | 2.10 |
2026 | 31 | < 0.02 | < 0.02 | 0.02 | 28.00 | 0.05 | < 0.02 | < 0.02 | 2.07 |
2027 | 31.3 | < 0.02 | < 0.02 | < 0.02 | 28.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 50.9 | < 0.02 | < 0.02 | < 0.02 | 28.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 51 | 201.47 | 34.181 | 0.03 | 28.00 | 0.05 | < 0.02 | < 0.02 | 2.11 |
2020 | 51.1 | < 0.02 | < 0.02 | < 0.02 | 28.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 51.1 | < 0.02 | < 0.02 | < 0.02 | 28.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 51.1 | < 0.02 | < 0.02 | < 0.02 | 28.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 51.1 | < 0.02 | < 0.02 | < 0.02 | 28.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 51.2 | < 0.02 | < 0.02 | < 0.02 | 28.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 51.3 | < 0.02 | < 0.02 | < 0.02 | 28.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 63.7 | < 0.02 | < 0.02 | < 0.02 | 27.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 63.9 | < 0.02 | < 0.02 | < 0.02 | 27.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 63.9 | < 0.02 | < 0.02 | 1.45 | 27.56 | 0.20 | 0.03 | 0.17 | 4.05 |
2008 | 75.5 | < 0.02 | < 0.02 | 7.81 | 24.39 | 0.62 | < 0.02 | 0.35 | 9.74 |
2009 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 24.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 75.6 | < 0.02 | < 0.02 | < 0.02 | 24.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 75.6 | < 0.02 | < 0.02 | < 0.02 | 24.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 75.6 | < 0.02 | < 0.02 | < 0.02 | 24.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 75.6 | < 0.02 | < 0.02 | < 0.02 | 24.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 75.7 | < 0.02 | < 0.02 | < 0.02 | 24.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 100.1 | 129.78 | 34.341 | 12.46 | 22.12 | 0.89 | < 0.02 | 0.05 | 14.34 |
2006 | 125.7 | 127.51 | 34.438 | 15.75 | 18.86 | 1.12 | < 0.02 | 0.02 | 20.22 |
21 | 200.4 | 110.71 | 34.562 | 23.08 | 13.81 | 1.63 | < 0.02 | < 0.02 | 32.71 |
12004 | 210.1 | 114.02 | 34.532 | 23.74 | 12.98 | 1.68 | < 0.02 | < 0.02 | 35.14 |
12003 | 300.6 | 95.89 | 34.635 | 27.71 | 11.24 | 1.95 | < 0.02 | < 0.02 | 40.23 |
12002 | 400.5 | 90.62 | 34.698 | 30.79 | 9.65 | 2.13 | < 0.02 | < 0.02 | 43.63 |
12001 | 500.1 | 84.63 | 34.721 | 32.71 | 8.95 | 2.26 | < 0.02 | < 0.02 | 47.05 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |