Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 43
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-06-04 15:06 to 2019-06-04 15:52 UTC
Where: 12° 26.7' S 110° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 27.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 27.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 6 | < 0.02 | < 0.02 | 0.02 | 27.93 | 0.05 | 0.02 | < 0.02 | 2.53 |
2033 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 27.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 27.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 10.8 | 201.91 | 34.127 | 0.03 | 27.93 | 0.05 | < 0.02 | < 0.02 | 2.54 |
2029 | 24 | < 0.02 | < 0.02 | < 0.02 | 27.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 24 | < 0.02 | < 0.02 | 0.03 | 27.93 | 0.05 | < 0.02 | < 0.02 | 2.54 |
2026 | 34.8 | < 0.02 | < 0.02 | 0.02 | 27.93 | 0.05 | < 0.02 | < 0.02 | 2.53 |
2027 | 35 | < 0.02 | < 0.02 | < 0.02 | 27.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 50.9 | 201.42 | 34.120 | 0.02 | 27.92 | 0.05 | < 0.02 | < 0.02 | 2.56 |
2019 | 57.6 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 57.8 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 57.8 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 57.9 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 57.9 | < 0.02 | < 0.02 | 0.03 | 27.90 | 0.05 | < 0.02 | < 0.02 | 2.59 |
2023 | 57.9 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 58 | < 0.02 | < 0.02 | < 0.02 | 27.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 71.8 | < 0.02 | < 0.02 | 2.36 | 26.51 | 0.30 | 0.06 | 0.25 | 5.32 |
2016 | 71.8 | < 0.02 | < 0.02 | < 0.02 | 26.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 71.9 | < 0.02 | < 0.02 | < 0.02 | 26.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 24.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 80.6 | 151.89 | 34.244 | 7.17 | 24.69 | 0.58 | < 0.02 | 0.19 | 9.39 |
2013 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 86.5 | < 0.02 | < 0.02 | < 0.02 | 23.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 86.6 | 144.43 | < 0.02 | 8.47 | 23.94 | 0.67 | < 0.02 | 0.18 | 10.48 |
2006 | 101 | 140.99 | 34.267 | 9.35 | 23.55 | 0.72 | < 0.02 | 0.15 | 11.33 |
21 | 126.1 | 132.42 | 34.595 | 12.17 | 20.89 | 0.89 | < 0.02 | 0.03 | 14.39 |
12004 | 201.5 | 114.20 | 34.714 | 19.71 | 15.37 | 1.42 | 0.02 | < 0.02 | 26.94 |
12003 | 301.1 | 98.70 | 34.711 | 26.67 | 11.06 | 1.91 | < 0.02 | < 0.02 | 37.82 |
12002 | 400.1 | 102.27 | 34.699 | 29.05 | 9.50 | 2.06 | < 0.02 | < 0.02 | 41.86 |
12001 | 500.9 | 80.66 | 34.703 | 32.82 | 8.56 | 2.34 | < 0.02 | < 0.02 | 52.57 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |