Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 33
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-05-31 22:55 to 2019-06-01 02:54 UTC
Where: 16° 59.9' S 110° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2132 | 4.9 | 206.11 | 34.583 | < 0.02 | 27.03 | 0.03 | < 0.02 | < 0.02 | 1.71 |
2033 | 5 | < 0.02 | < 0.02 | < 0.02 | 27.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 5 | < 0.02 | < 0.02 | < 0.02 | 27.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 27.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 27.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 9.5 | 205.93 | 34.583 | < 0.02 | 27.03 | 0.02 | < 0.02 | < 0.02 | 1.71 |
2030 | 25.8 | 206.07 | 34.583 | < 0.02 | 27.03 | 0.02 | < 0.02 | < 0.02 | 1.72 |
2029 | 49.9 | 208.57 | 34.771 | < 0.02 | 26.71 | 0.03 | < 0.02 | < 0.02 | 1.91 |
2028 | 74.8 | 209.95 | 34.873 | < 0.02 | 26.39 | 0.05 | < 0.02 | < 0.02 | 2.35 |
2022 | 95 | 197.40 | 34.920 | 1.05 | 23.10 | 0.22 | < 0.02 | 0.30 | 4.59 |
2020 | 95 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 95 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 95.1 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 95.1 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 95.1 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 95.2 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 95.2 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 95.2 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 95.2 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 95.2 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 100.2 | 182.44 | 34.913 | 3.24 | 22.48 | 0.35 | < 0.02 | 0.28 | 5.90 |
2016 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 22.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 125.3 | 181.41 | < 0.02 | 3.92 | 21.52 | 0.36 | < 0.02 | 0.02 | 5.34 |
1214 | 125.3 | < 0.02 | < 0.02 | < 0.02 | 21.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 150.2 | 146.44 | 35.110 | 10.66 | 19.58 | 0.75 | < 0.02 | < 0.02 | 11.84 |
2010 | 199.8 | 169.00 | 35.444 | 8.78 | 17.78 | 0.65 | < 0.02 | < 0.02 | 10.24 |
2011 | 199.9 | < 0.02 | < 0.02 | < 0.02 | 17.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 300.3 | 166.50 | 35.059 | 16.12 | 12.78 | 1.14 | < 0.02 | < 0.02 | 17.12 |
2008 | 399.8 | 207.85 | 34.803 | 17.74 | 10.22 | 1.22 | < 0.02 | < 0.02 | 11.40 |
1201 | 500.5 | 181.23 | 34.649 | 24.30 | 8.69 | 1.64 | < 0.02 | < 0.02 | 21.04 |
2006 | 1000.3 | 92.05 | 34.643 | 37.27 | 5.17 | 2.69 | < 0.02 | < 0.02 | 94.26 |
21 | 2001 | 144.26 | 34.721 | 36.05 | 2.47 | 2.56 | < 0.02 | < 0.02 | 122.57 |
12004 | 3001 | 173.46 | 34.723 | 34.86 | 1.64 | 2.43 | < 0.02 | < 0.02 | 130.21 |
12003 | 4000.6 | 193.38 | 34.717 | 34.13 | 1.24 | 2.35 | < 0.02 | < 0.02 | 131.93 |
12002 | 4999.6 | 200.62 | 34.713 | 33.81 | 1.20 | 2.32 | < 0.02 | < 0.02 | 130.69 |
12001 | 5724.9 | 203.79 | 34.711 | 33.70 | 1.25 | 2.31 | < 0.02 | < 0.02 | 129.82 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |