Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 15
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-05-22 22:54 to 2019-05-23 02:36 UTC
Where: 30° 30.1' S 110° 00.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2033 | 4 | < 0.02 | < 0.02 | < 0.02 | 20.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 4 | 229.74 | 35.897 | < 0.02 | 20.34 | 0.04 | < 0.02 | < 0.02 | 1.98 |
2034 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 20.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 20.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 20.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 11.5 | 229.96 | 35.897 | < 0.02 | 20.34 | 0.03 | < 0.02 | < 0.02 | 2.01 |
2030 | 25.6 | < 0.02 | < 0.02 | < 0.02 | 20.35 | 0.04 | < 0.02 | < 0.02 | 2.08 |
2029 | 51.3 | 229.56 | 35.896 | < 0.02 | 20.35 | 0.04 | < 0.02 | < 0.02 | 2.07 |
2028 | 75.8 | 229.56 | 35.896 | 0.02 | 20.34 | 0.04 | < 0.02 | < 0.02 | 2.08 |
2027 | 101.5 | 229.02 | 35.920 | 0.06 | 19.85 | 0.06 | 0.04 | 0.03 | 1.86 |
2020 | 124.4 | 226.92 | 35.814 | 0.79 | 18.39 | 0.15 | < 0.02 | 0.04 | 1.89 |
2021 | 124.4 | < 0.02 | < 0.02 | < 0.02 | 18.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 124.5 | < 0.02 | < 0.02 | < 0.02 | 18.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 124.5 | < 0.02 | < 0.02 | < 0.02 | 18.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 124.5 | < 0.02 | < 0.02 | < 0.02 | 18.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 124.6 | < 0.02 | < 0.02 | < 0.02 | 18.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 124.8 | < 0.02 | < 0.02 | < 0.02 | 18.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 135.7 | 226.92 | 35.811 | 1.04 | 17.88 | 0.18 | < 0.02 | 0.04 | 1.83 |
2018 | 151.4 | 223.08 | 35.771 | 1.79 | 17.23 | 0.22 | < 0.02 | < 0.02 | 1.83 |
2017 | 200.9 | < 0.02 | < 0.02 | < 0.02 | 15.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 201 | 236.12 | 35.558 | 2.80 | 15.12 | 0.32 | < 0.02 | < 0.02 | 1.31 |
1214 | 301 | < 0.02 | < 0.02 | < 0.02 | 12.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 301 | 245.68 | 35.110 | 7.85 | 12.24 | 0.64 | < 0.02 | < 0.02 | 1.70 |
2009 | 352 | 247.56 | 34.949 | 10.65 | 11.18 | 0.80 | < 0.02 | < 0.02 | 2.31 |
2012 | 352.1 | < 0.02 | < 0.02 | < 0.02 | 11.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 352.1 | < 0.02 | < 0.02 | < 0.02 | 11.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 352.2 | < 0.02 | < 0.02 | < 0.02 | 11.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 352.2 | < 0.02 | < 0.02 | < 0.02 | 11.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 401 | 250.46 | 34.838 | 12.58 | 10.46 | 0.92 | < 0.02 | < 0.02 | 2.85 |
1201 | 502.1 | 247.38 | 34.707 | 15.86 | 9.58 | 1.11 | < 0.02 | < 0.02 | 3.98 |
2006 | 1000.5 | 152.20 | 34.491 | 35.19 | 4.51 | 2.44 | < 0.02 | < 0.02 | 62.75 |
21 | 2000.8 | 163.01 | 34.707 | 34.87 | 2.40 | 2.42 | < 0.02 | < 0.02 | 105.11 |
12004 | 3001.5 | 183.74 | 34.728 | 33.98 | 1.69 | 2.34 | < 0.02 | < 0.02 | 118.82 |
12003 | 3999.8 | 198.38 | 34.718 | 33.74 | 1.26 | 2.32 | < 0.02 | < 0.02 | 126.15 |
12002 | 4996.1 | 209.01 | 34.711 | 33.38 | 1.10 | 2.29 | < 0.02 | < 0.02 | 126.11 |
12001 | 5480.7 | 211.43 | 34.709 | 33.30 | 1.11 | 2.28 | < 0.02 | < 0.02 | 126.15 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |