Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 14
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-05-22 12:09 to 2019-05-22 12:47 UTC
Where: 31° 57.5' S 109° 59.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2031 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 6.5 | 233.00 | 35.991 | 0.03 | 19.46 | 0.04 | < 0.02 | < 0.02 | 1.69 |
2132 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 10.7 | 233.00 | 35.991 | 0.03 | 19.46 | 0.04 | < 0.02 | < 0.02 | 1.71 |
2027 | 24.8 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 25.3 | 233.00 | 35.991 | 0.03 | 19.46 | 0.04 | < 0.02 | < 0.02 | 1.73 |
2028 | 26 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 40.1 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 40.3 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 40.7 | 232.91 | 35.990 | 0.03 | 19.46 | 0.04 | < 0.02 | < 0.02 | 1.72 |
2022 | 51.1 | 233.09 | 35.991 | 0.02 | 19.46 | 0.04 | < 0.02 | < 0.02 | 1.74 |
2020 | 68.1 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 68.2 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 68.3 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 68.4 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 68.4 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 68.4 | 232.64 | 35.990 | 0.03 | 19.46 | 0.03 | < 0.02 | < 0.02 | 1.72 |
2015 | 82.6 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 82.7 | 232.55 | 35.990 | 0.03 | 19.46 | 0.03 | < 0.02 | < 0.02 | 1.71 |
1214 | 83 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 100.3 | 232.42 | 35.990 | 0.03 | 19.46 | 0.03 | < 0.02 | < 0.02 | 1.72 |
2010 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 100.6 | < 0.02 | < 0.02 | < 0.02 | 19.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2006 | 125.2 | 232.28 | 35.979 | 0.05 | 19.46 | 0.04 | < 0.02 | < 0.02 | 1.71 |
21 | 171 | 229.56 | 35.705 | 1.52 | 16.68 | 0.22 | < 0.02 | 0.02 | 1.53 |
12004 | 200.9 | 230.72 | 35.616 | 2.45 | 15.86 | 0.28 | < 0.02 | < 0.02 | 1.45 |
12003 | 299.5 | 242.60 | 35.059 | 9.05 | 12.07 | 0.71 | < 0.02 | < 0.02 | 1.97 |
12002 | 400.2 | 238.94 | 34.647 | 18.24 | 9.05 | 1.26 | < 0.02 | < 0.02 | 5.79 |
12001 | 501 | 213.03 | 34.513 | 24.16 | 7.57 | 1.63 | < 0.02 | < 0.02 | 12.84 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |