Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-05-20 23:09 to 2019-05-21 01:11 UTC
Where: 33° 29.9' S 110° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 5.4 | 237.86 | 35.912 | 0.03 | 18.17 | 0.06 | < 0.02 | < 0.02 | 1.48 |
2033 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 10.9 | 237.91 | 35.912 | 0.03 | 18.18 | 0.06 | < 0.02 | < 0.02 | 1.47 |
2030 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 18.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 25.7 | 237.82 | 35.912 | 0.02 | 18.17 | 0.06 | < 0.02 | < 0.02 | 1.44 |
2026 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 51.5 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 51.6 | < 0.02 | < 0.02 | < 0.02 | 18.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 51.8 | 237.64 | 35.909 | 0.03 | 18.17 | 0.06 | < 0.02 | < 0.02 | 1.43 |
2022 | 75.6 | 237.86 | 35.910 | 0.03 | 18.18 | 0.06 | < 0.02 | < 0.02 | 1.46 |
2021 | 100.9 | 238.09 | 35.899 | 0.03 | 18.15 | 0.06 | < 0.02 | < 0.02 | 1.44 |
2020 | 125.6 | 240.01 | 35.688 | 0.44 | 17.10 | 0.13 | < 0.02 | 0.13 | 1.03 |
2019 | 135.5 | 239.65 | 35.622 | 1.00 | 16.32 | 0.19 | < 0.02 | 0.07 | 1.11 |
2018 | 148.7 | 236.39 | 35.626 | 1.49 | 15.97 | 0.23 | < 0.02 | 0.02 | 1.27 |
2017 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 13.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 200.6 | 242.51 | 35.321 | 4.68 | 13.70 | 0.44 | < 0.02 | < 0.02 | 1.27 |
2012 | 220.7 | < 0.02 | < 0.02 | < 0.02 | 13.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 220.8 | < 0.02 | < 0.02 | < 0.02 | 13.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 220.9 | < 0.02 | < 0.02 | < 0.02 | 13.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 221 | < 0.02 | < 0.02 | < 0.02 | 13.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 221.1 | 244.97 | 35.230 | 5.66 | 13.09 | 0.50 | < 0.02 | < 0.02 | 1.27 |
1214 | 221.1 | < 0.02 | < 0.02 | < 0.02 | 13.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 299 | 252.87 | 35.016 | 8.51 | 11.75 | 0.68 | < 0.02 | < 0.02 | 1.67 |
2008 | 400.4 | < 0.02 | < 0.02 | < 0.02 | 10.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 400.5 | 253.50 | 34.817 | 12.58 | 10.39 | 0.92 | < 0.02 | < 0.02 | 2.79 |
2006 | 500.7 | 249.61 | 34.725 | 15.23 | 9.72 | 1.08 | < 0.02 | < 0.02 | 3.72 |
21 | 1000.6 | 191.60 | 34.388 | 32.86 | 4.25 | 2.24 | < 0.02 | < 0.02 | 42.84 |
12004 | 2000.3 | 169.31 | 34.704 | 34.15 | 2.38 | 2.37 | < 0.02 | < 0.02 | 98.66 |
12003 | 2300.6 | 176.28 | 34.725 | 33.78 | 2.07 | 2.34 | < 0.02 | < 0.02 | 107.44 |
12001 | 2615 | 181.64 | 34.730 | 33.52 | 1.91 | 2.32 | < 0.02 | < 0.02 | 110.03 |
12002 | 2615 | < 0.02 | < 0.02 | < 0.02 | 1.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |