Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-05-19 23:44 to 2019-05-20 03:06 UTC
Where: 35° 00.0' S 109° 59.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2132 | 5 | 237.06 | 35.856 | 0.07 | 18.21 | 0.07 | < 0.02 | 0.02 | 1.42 |
2035 | 5 | < 0.02 | < 0.02 | < 0.02 | 18.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 18.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 18.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 18.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 9.6 | < 0.02 | < 0.02 | < 0.02 | 18.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 9.8 | < 0.02 | < 0.02 | < 0.02 | 18.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 18.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 10.3 | < 0.02 | < 0.02 | < 0.02 | 18.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 18.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 10.8 | 237.28 | 35.856 | 0.07 | 18.21 | 0.07 | < 0.02 | 0.02 | 1.42 |
2024 | 25 | 237.42 | 35.855 | 0.08 | 18.13 | 0.07 | < 0.02 | 0.03 | 1.37 |
2025 | 25.3 | < 0.02 | < 0.02 | < 0.02 | 18.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 51.2 | 239.43 | 35.845 | 0.05 | 17.77 | 0.07 | < 0.02 | < 0.02 | 1.18 |
2018 | 76.7 | < 0.02 | < 0.02 | < 0.02 | 17.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 76.8 | < 0.02 | < 0.02 | < 0.02 | 17.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 76.8 | < 0.02 | < 0.02 | < 0.02 | 17.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 76.9 | < 0.02 | < 0.02 | < 0.02 | 17.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 76.9 | < 0.02 | < 0.02 | < 0.02 | 17.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 77 | < 0.02 | < 0.02 | < 0.02 | 17.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 77 | 239.56 | 35.843 | 0.04 | 17.76 | 0.07 | < 0.02 | < 0.02 | 1.16 |
2015 | 100.8 | 239.56 | 35.842 | 0.04 | 17.76 | 0.07 | < 0.02 | < 0.02 | 1.15 |
1214 | 126 | 240.28 | 35.770 | 0.26 | 17.51 | 0.10 | < 0.02 | 0.04 | 1.09 |
2013 | 151.1 | 244.16 | 35.483 | 1.51 | 15.36 | 0.25 | < 0.02 | 0.03 | 0.87 |
2011 | 203 | 243.00 | 35.324 | 4.04 | 13.87 | 0.40 | < 0.02 | < 0.02 | 0.96 |
2012 | 203.2 | < 0.02 | < 0.02 | 4.04 | 13.87 | 0.40 | < 0.02 | < 0.02 | 0.96 |
2010 | 300.5 | 248.14 | 35.012 | 8.73 | 11.70 | 0.69 | < 0.02 | < 0.02 | 1.59 |
2008 | 399.5 | 246.04 | 34.750 | 15.33 | 9.77 | 1.07 | < 0.02 | < 0.02 | 3.70 |
2009 | 399.7 | < 0.02 | < 0.02 | 15.29 | 9.77 | 1.07 | < 0.02 | < 0.02 | 3.73 |
1201 | 501 | 236.57 | 34.610 | 19.33 | 8.70 | 1.32 | < 0.02 | < 0.02 | 6.45 |
2006 | 1000.4 | 183.42 | 34.420 | 34.10 | 3.75 | 2.34 | < 0.02 | < 0.02 | 52.64 |
21 | 1802.4 | 166.32 | 34.678 | 34.49 | 2.56 | 2.40 | < 0.02 | < 0.02 | 92.83 |
12004 | 1999 | 169.27 | 34.706 | 34.15 | 2.37 | 2.37 | < 0.02 | < 0.02 | 99.47 |
12003 | 3002.7 | 187.93 | 34.730 | 33.43 | 1.71 | 2.31 | < 0.02 | < 0.02 | 114.78 |
12002 | 4000.8 | 199.50 | 34.719 | 33.46 | 1.25 | 2.31 | < 0.02 | < 0.02 | 125.31 |
12001 | 4851.2 | 211.34 | 34.708 | 33.16 | 1.02 | 2.28 | < 0.02 | < 0.02 | 125.87 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |