Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70677,Oxygen CTD 24-SBE 43-SN 1794,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6130,Transmissometer - CTD 24 -CST-1421DR
When: 2019-05-15 01:53 to 2019-05-15 02:38 UTC
Where: 34° 42.4' S 113° 25.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
32 | 4.4 | 237.24 | < 0.02 | < 0.02 | 18.61 | 0.07 | < 0.02 | < 0.02 | 1.61 |
36 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 18.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.6 | < 0.02 | 35.825 | < 0.02 | 18.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 18.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 18.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 10.6 | 237.42 | 35.822 | < 0.02 | 18.61 | 0.07 | < 0.02 | < 0.02 | 1.61 |
30 | 25.2 | 240.05 | 35.759 | < 0.02 | 18.01 | 0.08 | < 0.02 | < 0.02 | 1.16 |
29 | 50.4 | 240.81 | 35.693 | 0.11 | 17.39 | 0.12 | 0.09 | 0.05 | 1.06 |
27 | 74.7 | < 0.02 | < 0.02 | < 0.02 | 16.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 74.7 | < 0.02 | < 0.02 | < 0.02 | 16.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 74.8 | < 0.02 | < 0.02 | < 0.02 | 16.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 74.8 | 246.98 | 35.633 | 0.02 | 16.68 | 0.12 | 0.02 | < 0.02 | 0.69 |
28 | 74.8 | < 0.02 | < 0.02 | < 0.02 | 16.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 74.8 | < 0.02 | < 0.02 | < 0.02 | 16.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 16.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 100.3 | 246.22 | 35.566 | 0.39 | 16.26 | 0.16 | 0.15 | 0.07 | 0.68 |
21 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 16.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 110.4 | < 0.02 | < 0.02 | < 0.02 | 16.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 110.5 | < 0.02 | < 0.02 | < 0.02 | 16.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 110.6 | 247.24 | 35.562 | 0.40 | 16.16 | 0.17 | 0.20 | 0.06 | 0.67 |
19 | 110.6 | < 0.02 | < 0.02 | < 0.02 | 16.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 110.7 | < 0.02 | < 0.02 | < 0.02 | 16.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 123.6 | 246.93 | 35.448 | 1.32 | 15.64 | 0.23 | 0.18 | 0.14 | 0.67 |
13 | 150.1 | 241.57 | 35.332 | 3.61 | 14.03 | 0.39 | < 0.02 | 0.02 | 0.94 |
12 | 165.1 | 242.29 | 35.283 | 4.33 | 13.65 | 0.43 | < 0.02 | 0.02 | 0.96 |
11 | 201 | 246.22 | 35.157 | 6.08 | 12.73 | 0.54 | < 0.02 | 0.02 | 1.16 |
10 | 301.7 | 255.01 | 34.859 | 11.00 | 10.71 | 0.83 | < 0.02 | < 0.02 | 2.26 |
9 | 402.1 | 250.64 | 34.741 | 14.57 | 9.82 | 1.04 | < 0.02 | < 0.02 | 3.43 |
1 | 501.9 | 248.58 | 34.695 | 16.03 | 9.43 | 1.12 | < 0.02 | < 0.02 | 4.04 |
5 | 502 | < 0.02 | < 0.02 | < 0.02 | 9.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 502 | < 0.02 | < 0.02 | < 0.02 | 9.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 502.1 | < 0.02 | < 0.02 | < 0.02 | 9.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 502.1 | < 0.02 | < 0.02 | < 0.02 | 9.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 502.1 | < 0.02 | < 0.02 | < 0.02 | 9.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 502.2 | < 0.02 | < 0.02 | < 0.02 | 9.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 502.3 | < 0.02 | < 0.02 | < 0.02 | 9.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Temperature CTD 24 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |